Ron B for Model Number GU1500XTLS2 My unit has pwr. To it, but the control panel w/n work properly causing the unit not to work. When i unplug & replug the 120 vac cord to reset it, the normal & rinse cycle led's come on & the no. 2 is displayed in the window. I do here the drain pump working for a short while then it stops. After that happens the normal & rinse cycle led's start flashing & the time remaining window has 2 green steady "on" dashes. No other buttons on the control panel light-up when pressed. I do notice the anti-bacterial & pots/pans buttons do not have that spring back feel to them like the other buttons do on the c/p.
Answer Ron, With the normal and rinse cycle keys flashing, this would be an indication of a stuck keypad in which the control panel would need to be replaced. The part number for the control panel for this unit is WP8534839. Read More... Answered by AppliancePartsPros.com | Tuesday, November 18, 2014