Arlyn F. for Model Number KUDI01ILB6 Had 3 lights, cancel button would start pump, wouldn't run. Ordered board as advised, had 1 lite and nothing worked. Asked question on line, was sent wiring diagram with instructions to test switches in panel. Tested switches with DVOM using both the ohm reader, and diode scale of the meter and all tested OK. Was sent another board, installed Sat. and it ran fine. Mon only one lite would lite and unit would not run. Removed panel again and tested with ohm meter again, all buttons checked OK, then tested again using diode test of the meter and 2 buttons give a forward reading of 3.1 volts. Could a bad control board cause the diodes to short or is this really a short or just a forward bias inherent to these components. Please help.Thanks Arlyn.
Answer Hi Arlyn. What exact light is coming on? The soil sensor will emit a code when it has failed. The sensor is part # WP8269208. Check the heating element to see if it is open. Should read 28-32 ohms. Make sure it is not shorted. Make sure the ribbon cable is plugged in securely. You need to use dishwasher monthly to keep all operating correctly. Part # is TJ104. Thank you Read More... Answered by AppliancePartsPros.com | Thursday, September 29, 2011