Bob for Model Number Maytag Dryer Model MDG5500AWW Hi. I also have the same issue with igniter glows red, gas fires up for about 15 seconds then both igniter and gas shut off completely. Based on my reading in this thread that igniter may be weak but it passed continuity test. Is the igniter has to be glowing red hot entirely during drying cycle? I replaced new coil but still experience the same issue?
Answer Hi Bob. This can be a plugged or kinked vent or a flame sensor that prematurely opens part # WP338906. Make sure the vent is entirely clear and not restricted. Make sure the outside vent cap / hood is opening and closing properly 4-5x /yr. so lint and moisture does not back up and create a restriction causing these issues. The igniter part # 4391996 should ohm out to 50-400 ohms at room temperature. Use a volt/ohm meter part #@ MA-DM1 to assist you in your diagnostics. Look at the center of the igniter and see if there is a hairline crack that may open during heating. Are there any lint built up around the motor ? Are you getting 120 vac to the dryer and the cord connections tight ? Are you getting 24 dc at the heater relay on the board. Ohm out the heater relay coils and see if they are between 350-450 ohms. Does the relay contacts close and send the 120 vac onto the wire and then the relay prematurely opens? The dryer thermistor part # 307208 on the blower housing should read 10,000 ohms at 77°. If it is more then 10% value then replace it. It will be advantageous to find the supplied tech sheet inside the cabinet to aid you in the diagnosis. It allows you to put the unit in a diagnostic mode which brings up fault codes and tells you which circuit needs assistance. Thank You. Read More... Answered by AppliancePartsPros.com | Friday, May 4, 2012