Larry for Model Number KUDS01DLSS2 In response to your previous answer I dont have heated dry and normal on my machine. I have also put a glass in the upper rack and no water goes into the glass as ive seen in other posts. Could it be the themister or a bad pump? I checked the chopper and screen and they were clear. I tested the thermister and it showed continuity.
Answer Hi Larry. You need to check the entire water manifold system to make sure the wash arm in question is coupled into the back manifold correctly. Is everything intact ? Is the rack upper and lower adjustment cocked to one side and not allowing the manifold to enter the manifold probe correctly for water ? If the rack is not adjusted together side to side, then the manifold will be misguided not entering the back water supply tube. If all this is correct then you need to clean the wash arm jet holes for clog with a pick tool. Then flush out under the sink- inverted. Have you cleaned the entire sump filter area down to the chopper blade level so there are no debris blocking the internal pump pressure ? Try all of this and let us know how to assist. further w/ poss. parts needed. Thank You. Read More... Answered by AppliancePartsPros.com | Thursday, January 26, 2012