Answer Marian, the water valve and thermistor assembly W11210459 would need to be tested. At room temperature, the thermistor should have a resistance reading of 40 to 50 Ohms. The valve solenoids would need to be tested for voltage when set to warm. The hot water and cold water connections should receive 120VAC as cold or hot water is needed to reach the necessary temperature. If either valve does not receive voltage and the thermistor tested good, then the failure would be in the main control W11170319. Read More... Answered by AppliancePartsPros.com | Tuesday, August 3, 2021