Mike L. for Model Number Maytag CWE900 In attempting to replace the upper broiler element, I found that the wire connection on one side had melted off. The wire on that side remains intact and looks OK, but the connector on the end of it is burned mostly off. Can I put a new wire clip on it and reinstall, or does the meltoff indicate that I need professional help?
Answer Mike, At this point , you can replace the wire terminal, just make sure it is rated as, a high temperature, 240 Volt,30 amp. wire terminal, (not the light weight "brass colored ones) and that you get a very good attachment(crimp) when you secure the terminal to the wire, and yopu'll be fine, as long as theres no other damage to the other comonents, sounds like you'll be fine at this point. Good Luck and Thanks Read More... Answered by AppliancePartsPros.com | Tuesday, April 12, 2011