Joe for Model Number Whirlpool GI15NDXZQ2 Under counter ice maker was filling and overflowing water reservoir. Determined water fill sensor was bad. Installed new pump/sensor W11542867. Water now fills and turns off but water level is lower than overflow hole (not quite enough water). As a result, ice is thin as cycle only runs 8 min and fill sensor seems to sense water is lower than it is, stopping the cycle and pumping out remaining water. It’s as if fill sensor isn’t calibrated properly. Installed a second new pump and same result. If I add additional water to reservoir right when pump starts and cycle begins, cycle runs 24 minutes and makes great ice. How do I get fill sensor to work properly? Can I adjust I somehow?