Ed for Model Number med6600tqo Hello I have a maytag bravo electric dryer med6600tqo that will not start, it lights up I have 240v, I ran a diagnostic and it gives me fault 25 the thermistor is not open, maybe shorted? I checked the high limit thermostat it is good, but the moisture sensor located in the drum is open? would that stop it from starting? also when you hit the start button should it click? I did not check the door switch? I don't think it clicked before? thanks
Answer Ed, You will want to do a resistance check on the exhaust thermistor. The resistance should be at 80 degrees 8.5 to 10.5K ohms at 70 degrees 11.5 to 13.5 k ohms. If outside this range then you would need to replace the thermistor. Read More... Answered by AppliancePartsPros.com | Tuesday, March 12, 2013