Jarhead for Model Number GI15NDXXS1 I have a Whirlpool GI15NDXXS1 under counter ice maker. It stopped filling with water recently, so I changed out the valve (Valve WPW10340983 / AP6019930) and it didn't work. I then tried the sensor (Sensor WPW10548509 / AP6022829) and it still does not fill with water. I don't know what else to try at this point. I know just because the part is new does not mean it is good. the sensor is reading 10.2 Ohm so I think that is good. Any suggestions? Jarhead for Model Number GI15NDXXS1 ANSWER Jarhead, Check to make sure that the water line is not frozen between the valve and the reservoir. If it is not then test to make sure that there is 120 Vac getting to the valve when it is supposed to fill with water. If it is not then the issue will be with the control board. My follow-up question is as follows- I know it is not the frozen issue since I am just turning the maker on. I tested the black and white wires on the valve and it seems as if it has a constant 120v so I think I am doing something wrong. Can you explain how I test the voltage (which wires perhaps). Or is their a way to test the main board or just replace it and see if it turns on? The Arizona summer is coming my way and I would love to get this ice maker working soon. Thank you for your help.
Answer Jarhead, Check to see if the water line between the fill valve and the reservoir is frozen. If it is then thaw it and put some insulation around it to keep it from freezing. If it is not then this would most likely be a control board issue. Read More... Answered by AppliancePartsPros.com | Tuesday, May 3, 2022