Elmer G for Model Number kenmore 9117360190 The igniters click continuously, have disconnected high voltage leads at burner one at a time, no difference, checked all switches and wiring with ohm meter all ok. Ohms across input transformer, 750 as listed on schematic, it uses a harper -wyman kool lite no 6526, we tried another one that was 6520 all nos and wiring points are same, now we get no spark at all.
Answer Elmer, The most likely cause for the unit to have the igniters clicking continuously when in the off position would be a faulty ignition switch. You will want to check the switches and test with them in the off position for continuity. If there is continuity in the off position then the switch is bad. If they all check ok then it may be a faulty spark module. Read More... Answered by AppliancePartsPros.com | Monday, November 30, 2015