John B. for Model Number JDS9860AAP Burners will not light except manually with a flame. Purchased and replaced spark module but nothing changed. Spark module has 120 VAC when each burner is in the light position. Checked for short to ground on all wiring from the spark module to the igniters and found none. Igniters spark normally when one or both burners on each side are lit and the knob is in the light position. Removed the burners from the pan and cleaned out the crud but still no change. Any further suggestions?
Answer Hello John, If there is 120Vac to the spark module and gas from the valve, the issue is either a poor ground to the surface burners or the burners WP3403M075-10 are in need of replacement. Read More... Answered by AppliancePartsPros.com | Saturday, February 19, 2022