David for Model Number LGR7646JQ1 Motor runs but no heat. There is no voltage to the ignitor. I tested the contacts on the timer and the correct ones are closed. I took an ohm reading of the heat switch (cycle) and it was open. According to the wiring diagram there should be a resistance in the line. Would this keep the heat off altogether. According to the diagram the ignitor gets its power through the red contact of the timer then through the t'stats and thermal fuse. Need help with this one. Thanks.
Answer Hello David. Based on the information you provided, it sounds like the cycle switch WP3399639 is bad if it was open. Hope this helps. Read More... Answered by AppliancePartsPros.com | Wednesday, February 8, 2012