Victor for Model Number GMC275PDS07 Display on microwave/combo says DOOR and will not take any command.Does the door switch needs replacing?
Answer Victor, with the power supply to the appliance turned off, the door switches W10211972 would need to be tested for continuity. With the door open, the dog eared terminal and the farthest terminal should have continuity. When the door is closed, the dog eared terminal and the middle terminal only will have continuity if each switch is operating properly. Read More... Answered by AppliancePartsPros.com | Tuesday, January 5, 2021