Jim Mills for Model Number KEMC308SS01 Hello,I had a bulb go out in the microwave portion of the combo. I replaced the bulb per the manual. The old bulb was bad, I checked it with an ohm meter. Put everything together and still no light and now a "door" message on the display. Ok, pulled the microwave again and checked all three door switches with my ohm meter and all check good. I went ahead and replaced them anyway. In addition I checked them in position by opening and closing the door. All looks good. Problem is I still have the "door" message and no light. I have checked the fuses with an ohm meter and they are also ok. What do you suspect is the problem and what should I check next? Thank you in advance!
Answer Jim, The cavity light not working, and the "door" in the display, indicates there is no 120 VAC to the control board. Heres some help, be careful, these are live voltage checks : At the red wire on the primary door switch, there should be 120 VAC to chassis ground, with the power applied to the oven, No voltage would indicate an open fuse, cavity thermal cut out, or broken wire. No 120 VAC at P 8 pin 1 (black) wire, door closed would be a bad door switch or broken wire. No 120 volts at p10 pin 1 (brown) wire, door open would be a bad door switch or broken wire(these checks are at the main control board and made to chassis ground) if voltages are proper you'd have a bad control board. Thanks and Good Luck Read More... Answered by AppliancePartsPros.com | Thursday, November 10, 2011