Microwave won't start or shows door error? A faulty door switch prevents operation when the door isn't detected as closed. DIY repair in under an hour.

More
$32.64

IN STOCK
Ships Monday Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Microwave Door Switch (Part Number: OEM13289769)

View all Questions

Answer

Heath, this can be caused by one of the interlock cams closing up. With the power supply cord unplugged, it would be recommended that the upper and lower interlocks are checked to see if they are in the closed position. If one of them is locked, it can be moved to the open position from behind the control panel and it would be recommended that the door switches are tested for continuity to identify if any have failed. The top right and bottom-left switch should have continuity with the door open. The top left and bottom-right switches should not have continuity when the door is open. If a switch fails, it would be recommended that the corresponding interlock is changed if it is the upper use the part number W11182140 and for the lower use the part number W11182141.

Read More...

Answered by AppliancePartsPros.com   |   Wednesday, February 24, 2021

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google