Ryan for Model Number 110.69822801 The dryer went absolutely dead in the middle of the cycle. Light bulb inside drum went off too. 240 voltage is present at the terminal box inside the dryer. I checked blower fuse, heater, both thermostats on heater, motor switch and door switch for continuity. They all checked out. Will timer cause the dryer to go dead along with the light bulb? If 240 is present at terminal then which part supplies 120 volts to the light bulb?
Answer Ryan, Test the door switch as it would be the most likely cause for the unit to just go dead and not have light inside the drum on. Read More... Answered by AppliancePartsPros.com | Friday, November 26, 2021