Mark for Model Number NT19L9 I have an Admiral Ref. and I was wondering what terminal do I place the black lead on? (Defrost Timer Part#4391974)
Answer Hello Mark, You will put the black wire on terminal number 1. This is a continuious configuration as the unit calls for a defrost cycle every 6 hours. Read More... Answered by AppliancePartsPros.com | Friday, October 18, 2013