This refrigerator defrost timer automatically starts and ends the defrost cycle to melt frost from the evaporator coils. Replacing a failed timer restores consistent cooling performance and helps prevent frost buildup that can restrict airflow.

  • Controls the timed switch between cooling and defrost to keep evaporator coils clear of frost
  • Common symptoms of failure: heavy frost on the evaporator or back panel, fresh food section too warm, unit runs constantly, or won't resume cooling after defrost
  • Restores proper frost removal and airflow for stable temperatures
  • Designed to match the original timer's function and wiring connections for applicable models
What's included: Defrost timer Install notes:
  • Disconnect power before servicing; wear cut-resistant gloves
  • Access location varies by model—often in the fresh food control housing or rear machine compartment
  • Photograph/label wire positions and transfer them to the matching terminals on the new timer
  • Reuse original mounting hardware and install in the same orientation as the original

More
$106.54
Compare At:
$126.78
You Save:
$20.24

IN STOCK
Ships Monday Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Defrost Timer (Refrigerator) (Part Number: OEM18030792)

View all Questions

Answer

Hello Jim. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the evaporator coils in the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

Answered by AppliancePartsPros.com   |   Tuesday, August 9, 2016

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store