Kurt for Model Number mtb2156dew should there be a continuity ready across 3 and 1. there is a resistor? between them 39k o>. is there a way to verify it is working.
Answer Kurt, Yes there should be a continuity reading between terminals 1 and 3 at the defrost timer. On the RX1 setting , you would read a closed circuit. the 39K ohms, is the timer motor winding resistance and the resistor. If the resistor was bad, you'd have no resistance reading. Good Luck. Read More... Answered by AppliancePartsPros.com | Monday, July 18, 2011