Scott for Model Number Maytag #MHWC7500YW0 A10 code appears well into the wash cycle. When you hit drain/cancel it drains out perfectly. So the pump and drain are in good shape with no obstructions. We cleaned out the hose, discharge hose and pump assembly to be sure there are not clogs or obstructions. It then seems to take quite a long time to open the door. Can the pressure switch cause an A10 code?
Answer Scott, the pressure switch [WPW10192975] can cause this to happen if it is sticking. However, the manufacturer steps for correcting this issue is once the pressure hose and coin catch have been verified as not being clogged, that the next step would be to replace the drain pump [WPW10465252]. Read More... Answered by AppliancePartsPros.com | Saturday, March 16, 2019