Ordered and replaced Temperature Sensor, Defrost Limiter Thermostat and Defrost Heater Bracket Assembly. Needed to use a blow dryer to melt ice on cooling unit. Replaced parts, everything is working fine. 1. Unplugged and replaced Defrost heater. 2. Cut wires to Temperature Sensor and Defrost Limiter thermostat used electrical butt connectors to reconnect the wires.