I dismantled the microwave and looked at the basic parts; magnetron. Inverter, capacitor and diode. All looked good. Measured connectivity of magnetron. Got zero vs half ohm. Ordered magnetron and for insurance ordered the inverter also.
Installed parts and it now working.
Only difficulty was taking out and putting back the screws some of which were very inaccessible.