Replaced the stirrer motor located inside the discharge vent. Vent cover, internal charcoal filter, and motor cover removed. Unplug the motor and remove the two screws holding the motor in position. Dropped the new motor replacement in place and reversed the steps.
The vent cover was removed by unscrewing the two Phillips screws located at the top of the grille cover (one on the top right and one on the top left). Slide the grille cover to the left with the microwave door closed and pull away from the unit.
The motor cover has one Phillips screw in the front center.
The motor required an off-set (right angle) screwdriver because of the limited space on the vent area.