I spent some time looking at the wiring diagram. I was not getting 120 volts, line to ground to the fan motor, therefore no cooling in refrigerator. I figured could be a couple of things since I don't have the computer board. The thermostat, the defrost heater or the timer. In the diagram I noticed that the fan received the ground through the defrost heater during normal operation. When the timer kicked in, there was 120 volts line to line on both sides of the fan which didn't allow it to work. I jumped the ground across one terminal and the fan worked. I checked continuity through the defrost heater and that was open. I replaced the defrost heater and the fridge is cooling again.