Gibson Refrigerator Defrost Timer, Adaptive Defrost Control

Best Seller
Gibson Defrost Timer
Genuine Frigidaire part
By: Frigidaire
Part Number: 215846602

The Defrost Timer is an OEM part for Frigidaire refrigerators. It is an essential electronic component that controls the automated defrost cycle of the refrigerator. The defrost timer monitors run times and temperatures to determine when to initiate the defrost process. It allows the refrigerator to operate efficiently by preventing excessive ice buildup. This defrost timer is designed to run for 30 minutes every 8 hours. 

Symptoms of a bad defrost timer include: 

  • Inability to initiate or maintain the defrost cycle 
  • Excessive ice buildup in the freezer compartment
  • Erratic temperature fluctuations
  • The refrigerator running excessively or displaying other performance issues

Causes of a bad defrost timer can be normal wear and tear over time. Environmental factors like power surges or fluctuations may also impact the electronic timer functionality. 

This OEM Frigidaire part can also be used on Electrolux, Frigidaire, Gibson, Kelvinator, Westinghouse, and Sears/Kenmore.

This part fixes the following symptoms
  • Frost buildup
  • Fridge runs too long
  • Freezer too cold
  • Freezer not defrosting
See more...
Do-It-Yourself Stories from Customers like You Not cooling properly eventually evaporator fan failure   Richard D. • Wood Ridge , NJ • April 25, 2016

My problem first showed up as varying temperature in both sections of my old mid 1970’s Frigidaire model FPCI-170T-7 refrigerator, which is not listed on most appliance repair databases. Running on the warm side from time to time, as well as sudden fan noise (probably the fan blade hitting ice build-up on the evaporator coil) alerted me to a possible defrost system problem, since the compressor was cooling. The evaporator fan eventually failed after a day or so, and a major repair was... Read more

More
$37.95
Compare At:
$45.54
You Save:
$7.59

IN STOCK
Ships Today Guaranteed
Add to Cart
Best Seller
Gibson Defrost Timer
Genuine Frigidaire part
By: Frigidaire
Part Number: 5304518034

The Defrost Timer is an OEM replacement part for Frigidaire upright freezers. It serves as a crucial component responsible for regulating automatic defrost cycles.

Causes of a faulty defrost timer relate to 20,000+ hours of constant exposure to freezer temperatures as low as -10 degrees Fahrenheit. Such extremes can compromise electrical switching mechanisms over prolonged usage periods.

Symptoms of a failed defrost timer include:

  • Inability to initiate automatic defrost modes  
  • Excessive ice and frost accumulation inside cabinet
  • Warm areas detected due to impaired fan circulation
  • Diagnostic codes indicating defrosting problems

This genuine Frigidaire replacement part is compatible with Kelvinator and some Kenmore units as well.

Do-It-Yourself Stories from Customers like You Freezer would not shut down kept running continuously   Jd F. • Russellville , AR • October 22, 2014

Suspected it was the thermostat, since temperature stayed the same at multiple settings over a 24 hr period. There was only three components inside the freezer besides the evaporator, the fan was working, so I decided to just go ahead and replace the thermostat and defrost thermostat. Also replaced the defrost timer by the compressor, just to get all the old parts replaced with new. I had already replaced the compressor, so now I've pretty much have a new freezer. The new parts works great and... Read more

More
$42.95
Compare At:
$51.11
You Save:
$8.16

IN STOCK
Ships Today Guaranteed
Add to Cart

Gibson refrigerator Defrost Timer, Adaptive Defrost Control are essential in keeping your fridge running smoothly and efficiently. These parts play a crucial role in maintaining the ideal temperature and preventing frost buildup, ensuring your food stays fresh. Without a fully functional defrost timer or adaptive defrost control, your Gibson refrigerator might struggle to regulate its internal climate, leading to potential food spoilage.

When it comes to Gibson refrigerator parts, the defrost timer and adaptive defrost control are indispensable. The defrost timer manages the intervals at which your refrigerator runs its defrost cycle, whereas the adaptive defrost control fine-tunes these cycles based on usage patterns, making them more energy-efficient. Having OEM replacement parts for these components guarantees they will fit perfectly and work seamlessly with your refrigerator, ensuring top-notch performance and longevity.

Whether you're dealing with an older model or a newer unit, maintaining or replacing these parts is key to the appliance's overall health. So, if you find yourself needing Gibson refrigerator Defrost Timer, Adaptive Defrost Control, rest assured that high-quality parts are readily available. These components are vital for the optimal functioning of your refrigerator, keeping your food fresh and your appliance in peak condition.