Thomas G Gulfport , MS October 16, 2022 Appliance: LG Room Air Conditioner LW1216ER/00 The compressor was running constantly even with the power button turned off I replaced the main circuit board because the compressor relay contact was welded shut (always closed), so the compressor would never shut off unless I pulled the power cord plug from the wall receptacle. To replace the main circuit board, first remove two Phillips head screws securing the A/C tray into the window mounting sleeve - they are located on the outdoors side of the unit towards the bottom corners of the window sleeve. Back indoors, remove the front grill from the unit - don't forget to remove it carefully because you have to disconnect the ribbon cable to the front control panel circuit board from the main circuit board enclosure header while holding the front grill with one hand - and then partially slide the tray out from the window sleeve to access the main circuit board enclosure located just behind where the front control panel normally resides. Remove three Phillips head screws from the top of the main circuit board enclosure, then remove the enclosure cover. Disconnect 3 ribbon cables from the circuit board headers and two wires with 1/4" quick disconnects from the compressor relay. Towards the front of the enclosure, remove one Phillips head screw securing the circuit board to the fixed part of the enclosure housing and then remove the original circuit board. Install the new circuit board, secure it with the one Phillips head screw at the side of the enclosure near the front, and reconnect the wires and ribbon cables to the compressor relay and circuit board headers. Reinstall the enclosure cover and secure it with the three Phillips head screws. Slide the unit back into the window sleeve and reinstall the front grill - don't forget to reconnect the front control panel ribbon cable to the main circuit board enclosure header. Reinstall the two Phillips head screws at the bottom rear corners of the window sleeve on the outdoor side of the unit to secure the tray to the window sleeve. The whole job took roughly 15 minutes tops. My window unit A/C is now running normally again. Read More... Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Screwdrivers
Douglas W Kittanning , PA April 25, 2021 AC compressor kept running on window unit. Bought a new mainboard. Read More... 15 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Screwdrivers
Kenneth R Clearwater , FL August 23, 2021 Appliance: LG Room Air Conditioner LW1216ER/00 The compressor would stay running after pushing power button to off. Replaced the main printed circuit board. All is well for now. Read More... 3 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
Troy S Sanford , FL May 19, 2026 The main control board Ordered another main control board from you guys Read More... Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Pliers, Screwdrivers
Daniel M Valley Stream , NY September 13, 2021 Appliance: LG Room Air Conditioner LW1216ER/00 LG lw1216er air conditioner compressor running nonstop even when the unit turned off. The replacement part arrived quickly, the next day after I ordered it. Just in time for more hot weather here. Replaced Main Board, EBR83604002. A straightforward repair requiring some disassembly. The Sanyou compressor control relay, SFK-112DM-GW is rattling. I will desolder it from the circuit board, and open up the case to see what failed. It is rated at 20A 250 Volts, and should have easily been able to handle the load from the compressor. The entire AC unit is rated at 9.2A 120 Volts. The unit is less than two season old. This repair saved me from a heavy lift job of unit replacement. More life left in it. Read More... Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Screwdrivers