1 Answer Mudahl, Control boards are not interchangeable as they may look the same but may have different functions built into them. Read More...
Dan July 02, 2021 for Model Number EI32AR65JS1 Can you tell me where the thermistor is located on this refrigerator? The diagram for parts does not show this one. Temperature goes roughly between 20 and 40 F. At low end freezes food and condensation on items from high end. Dan for Model Number EI32AR65JS1 ANSWER Dan, this can be caused by a failing or loosely connected thermistor 297110400, or it could be a failed main control 297326501. Commonly, the thermistor would be the more likely failure as it will weaken and cause improper temperatures. Answered by AppliancePartsPros.com | Thursday, July 1, 2021
Dan July 01, 2021 for Model Number EI32AR65JS1 Temperature goes roughly between 20 and 40 F. At low end freezes food and condensation on items from high end.
1 Answer Dan, this can be caused by a failing or loosely connected thermistor 297110400, or it could be a failed main control 297326501. Commonly, the thermistor would be the more likely failure as it will weaken and cause improper temperatures. Read More...
Evan R March 09, 2019 for Model Number EI32AF65JS1 Interior lights stopped functioning after a lightning strike to the home. All other features working normally. Replaced door switch and LED power board now lights are always on. Door switch is functioning with the door ajar alarm but not turning lights on or off. I've disconnected the LED power board for the time being. The only thing left to change would be the main control board, just wanting to make sure I'm not missing anything before swapping it out.
1 Answer Evan, double check your door switch, it should break the circuit for the lights. Try closing the switch with the door open. Check the switch for continuity, with it pushed in, there should not be continuity. If the switch checks out ok, replace the control. 241891608 Read More...
Thomas May 15, 2018 for Model Number E32AR85PQSB Have a Electrolux/Icon refrigerator, unit is always running, inside gets down to 19.0 degrees, replaced temp sensor and defrost stat, compressor still running very cold inside, any ideas, Thanks Tom
1 Answer Hello Thomas. You will need to order 297326501 for the electronic controller needed for the unit if the sensor is good on the unit. Thank you. Read More...
Holly M March 04, 2018 for Model Number kenmore elite refridgerator mod 2534474310 I cant control the temperature setting ,it is unstable
1 Answer Holly, The most likely cause for the unit working intermittently will be a faulty control board. Read More...