Larry O November 11, 2012 for Model Number LGGF3043KFM The gas range was new and set up for natural gas then converted to LP. Now I have natural gas in the house. Kept all of the removed orifices and instructions. However, I need the instructions to properly reinstall the right orifice to the right burner.
1 Answer Hello Larry, you can tell the orifices apart by the size of the hole in each one. You have 4 different sizes so I have listed below where I show they should be positioned according to the parts list for your model. Hope this helps! Right Front 316527509 Orifice 17KLeft Rear 316527511 Orifice 14KLeft Front / Center 316527500 Orifice 9.5K (2 used)Right Rear 316527504 Orifice 5K Read More...
Tony November 10, 2012 for Model Number FGFLMC55ECA Will this conversion kit work on my Frigidiare range model FGFLMC55ECA?
1 Answer Hi Tony, I could not find an LP conversion kit for this model so I looked up the User Manual and Installation Instructions. It looks like this model was not designed to be converted to LP gas. It states in the instructions, "DO NOT attempt to convert this range to L.P. (Propane) Gas. This appliance is designed to operate with Natural Gas only." That may explain why a kit could not be found. Thanks! Read More...
Ismael October 28, 2012 for Model Number frigidaire gallery lggf3043kfr gas range The lp conversion kit part#grlp3, is it the right one for my gas range, frigidaire gallery model: lggf3043kfr?
1 Answer Hello Ismael, you are correct. You need to order kit# GRLP3 for conversion to LP gas. Read More...
Brenda October 10, 2012 for Model Number VF05207916 New stove was natural gas.. I had to change it to propane when I purchased it. I now have natural gas in house and need to convert it back to natural gas. Cannot find parts from original and ordered orfices. Anyway, I need to know how to convert it back. We seem to be able to change the burners (not sure did it right) but what about the oven? do you have any instructions to help us?
1 Answer Hi Brenda, the model number given looks more like a serial number instead. Could you please send a valid model number and I can help you find the parts you need. Thanks! Read More...
Kball October 02, 2012 for Model Number fpgf3081kf Is there a way to change an orifice on this stove with out lifting the top. I thought you could, but I can't find a tool that will go down the hole to the hex head of the orifice.
1 Answer Hello Kball. Yes, just remove the screws securing the burners and remove the burners from the top. Then you can access and remove the orifices from the unit without raising the top of the unit. Read More...
Sally September 26, 2012 for Model Number TGF351AWC I don't want to pay $20 each the nat gas orifice spuds when an LP conversion kit that includes all of them is nearly $20! Why don't you offer a kit for both conversions? I am moving to the city where LP is not an option but my appliances are new enough I don't want to replace them, however, at that price I can pick up a used stove for less!
1 Answer Hello Sally. Sorry, but you will need to contact the manufacture for the reason why there is no kit. We do not have that information available. Thank you. Read More...
1 Answer Sally, the manufacturer does not offer a conversion kit for LP to NG. You will need to purchase the NG orifice 316237902. Thanks! Read More...
Joe September 18, 2012 for Model Number lggf3042kfj Converted to lp gas using kit grlp3 oven & broiler work fine stove top wont light at all ?
1 Answer Hello Joe. First, make sure the kit was installed properly into the unit. If so, make sure you fliped the regulator from natural gas to LP gas. Read More...
Gene F. September 08, 2012 for Model Number GLGF386DBG Is there a trick to unscrewing the orfices for a lp conversion? We tried to unscrew one and it broke off, they are very tight. Are they right or left handed threads?
1 Answer Hello Gene, These are right handed thread so counter-clockwise should remove them. Most are 7mm. They do tend to seize over time since the heat they are exposed to expands and contracts the metals so drastically. The only way this can be partially avoided is to apply some grease to the threads during the installation of the orifices. If you twisted one off,you will have to replace the ignitor/orifice assembly. If you try to drill and easy-out the old orifice, the assembly will have to be removed from the unit to get all of the metal slivers out since they will hamper the normal operation of the burner. You can try to heat the ignitor assembly first as this will expand the metal and they will sometimes release. The trick to this is after the metal has been heated, use an ice cube, touching only the orifice. This causes the orifice to contract and if the ignitor assembly is hot, it is expanded. This will SOMETIMES do the trick. Read More...
Timi July 28, 2012 for Model Number Bggf3042kf Am converting to lp gas and ordered part # AP4374168. I want to know if they come in sizeses or if they are the same size for the burners?
1 Answer Hello Timi! The LP Conversion kit GRLP3 will include the LP orifices for each burner, they will be different sizes. The kit will inlcude installation instructions for installation assistance. Thanks! Read More...