Gilberto February 13, 2018 for Model Number FGHS2634KW0 My refrigerator keeps freezing my food. The temperature readout for the refrigerator varies between 60 and 80 but the temperature inside is about 24 to 27 on a thermometer. The freezer readout varies between -20 and 6 and the temperature inside usually matches. I have tested the freezer and refrigerator thermistors and they both show 8.4k ohms at 77, I'm not sure what the specifications are. Is the problem in the thermistors or will there be a problem in the motherboard?
1 Answer Gilberto, If the resistance is showing good on the thermistor then this would most likely be a control board issue. Read More...
Belinda January 21, 2018 for Model Number LFUS2613LEO Prior to replacing the defrost thermostat the freezer temp would rise intermittently and especially if I had been cooking for hours. I removed the back panel in the freezer and discovered ice balls on the pipe leading from what I believe is the supply pipe on and below the thick goopy feeling tape and on the first bend. The temp was more stable with the ice balls. I defrosted them with a hair drier. Now after changing the defrost thermostat the freezer wasn't going below 12 degrees and at times 22 in the freezer and 35 in fridge. I triggered it to do a defrost cycle with the freezer light. After doing so the display finally registered -1/35 but it still rises more often to 22degrees. I had thermometers in both sides and the freezer overnight. In the morning it was at 5degrees and with food in fridge it registered at 40- 45. Why is it acting up more since I changed the thermostat? You do here the hiss of the freon when the unit is unplugged. So I am not to sure it's a freon problem yet.
1 Answer Belinda, If you are hearing the hiss of freon when the unit is unplugged then this will be a sealed system issue and will need to call service. Read More...
Jose December 14, 2017 for Model Number FGHS2631PF0 Ok my Fridge temperature was set on 37 but like a month ago it started to drop and freezes my Food and everything in there what would it be the problem that’s making the temperature to drop...
1 Answer Jose, This issue would most likely be that the damper assembly is faulty and will need to be replaced. You can test the sensor to make sure that the sensor is good. It should read 5K ohms at room temp. Read More...
Ed November 14, 2017 having a problem with a frigidaire side by side refrigerator. The freezer is fine but the fresh food side shows a hi or h1 code. Have unplugged it,checked the coils and reset it multiple times. Fan is running. What could it be ?
1 Answer Hello Ed. We will need your model number to help you with this. Please call 1-877-477-7278 or post your model number with a new question on the parts page. http://www.appliancepartspros.com/modelnumber_locator.aspx Read More...
James September 14, 2017 for Model Number FGHS2355PF4 Hello, my refrigerator side is not cooling. The main power board was replaced with no change. We are now leaning towards it being the thermistor (sensor) Where is this located in a side by side refrigerator? The error code on the display is OP as well.
1 Answer James, The issue with this error code will be a open thermistor and will want to check the thermistors to make sure that they are good. Read More...
1 Answer Joe, For the thermistor there is a cover over the thermistor on the side wall that you remove and then the thermistor will just unplug and plug back in. For the Damper there is a cover over it that is held in by a screw. Remove the screw and cover and then the damper should come out. Read More...
Derek August 01, 2017 for Model Number FGHS2631PF0 My freezer is working fine, but the fresh food side is not cooling. It stays at about 55° but the temperature reading on the digital display shows the temp as 33°. The condenser fan is running, the defrost thermostat shows continuity and there are no obstructions on the air intake. I cannot feel any airflow into the fresh food side. Do i have a bad controller?
1 Answer Hello Derek, If the defrost heater shows continuity and the evaporator fan motor in the freezer compartment is running, the main power board 5304497976 is the most likely issue. Read More...
Edgar R July 22, 2017 for Model Number FFus2613lso The freezer section works ok I can detect air flow from the fan but no air out in the refrigerator fresh food side, the damper door is open but no air comes through at all what is my problem
1 Answer Edgar, If the fan is blowing but nothing coming through the air duct then you will want to check to see if the return air duct behind the crispers is clear. If this checks ok then check the coils in the freezer are not impacted with ice. If it is then test the defrost heater and defrost thermostat to make sure that they have continuity. If they do then the issue will be a faulty control board. Read More...
Samantha July 13, 2017 for Model Number PHSB67EJSB0 The temp in my fridge keeps dropping to 27 degrees and freezing the food on the top 2 shelves. I have changed the damper mother board and compressor. What do you think needs to be changed? Samantha
1 Answer Samantha, There are several things to check before you replace anything. Check the controls, make sure the setting is F. (fahrenheit) , make sure the controls are set at 5 and 5 (mid range) This should produce a temperature of 38 dgrs F/F and 0 dgrs Frzr(+/- 3 dgrs.) Check the top shelf left side / corner. Make sure there's no large, tall or bulky items on the shelf, blocking or redirecting the air from the damper away from the thermistor , check all the shelves for articles hanging over the edges of the shelves, or against the side or rear walls. Let the refrigerator operate for 24 hours and recheck to see if both temperatures are in range. Read More...
David Unrot July 03, 2017 for Model Number FGHC2331PF7 My freezer temperature, which had always been 0 has suddenly risen to over 35. Resetting it has no effect. The fresh food section is normal at 37. I hear a clicking sound, like one a relay trying to reset might make. What do you think is the likely cause of the problem, do I need a service tech to fix it or could I do it myself?