Edm November 05, 2022 for Model Number GE PS920SF2SS The inner ring of the 12" 3 ring element does not work, but the outer 2 rings function. I checked and the element is ok but there is no voltage coming to it. I saw someone post this same problem on this website and was told that "the voltage to the user interface would come from the Merlin board WB27T11356 and if there is no voltage then the board will need to be replaced". However, on another experts' site I read "the relay board, mounted on the back of the range, that controls the power to the elements has failed. The board (Frame Board Asm WB27T11357 ) will need to be replaced. Since these are both expensive boards, how do I determine which is the problem?
1 Answer The Frame Board Assembly WB27T11357 is responsible for providing power to the element. Read More...
Alex September 21, 2022 for Model Number PS920SF3SS Does this board (WB27T11356) have relays that control the switching of the mains voltage to activate the cook top heating elements? Would a fault in this board explain why the inner ring of the 12" 3 ring element would NOT work, but the outer 2 rings would function OK?
1 Answer Alex, Yes, this board will have relays that control each of the inner and outer burner elements on the 12" element. Read More...
Stephen December 08, 2020 for Model Number PS920SF3SS unit is totally dead.there is 240v at terminal block and on the merlin pcb. the user interface has no dc voltage or ac. with out a schematic it appears that the dc for the user interface comes from the merlin3 pcb but i am not sure. the two thermostats located near the user interface are good.
1 Answer Stephen, The voltage to the user interface would come from the Merlin board WB27T11356 and if there is no voltage then the board will need to be replaced. Read More...
1 Answer Judah, This F640 error code is a No LIN communication between the main logic board and the induction bridge board. The things to check for would be to check the harness being open to the bridge board or the induction module or bridge module not getting power. Read More...