Pratik October 21, 2018 my dryer is running but the igniter doesn't stay lit for too long. like it turns on but the flame doesn't stay on long. i already changed the thermostat and solenoid coils
1 Answer Pratik, You will need to make sure your exhaust vent is clean all the way out of your home. A partially clogged vent will cause the unit to short cycle. Read More...
Debbie October 20, 2015 for Model Number DRSR495EG8WW Any instructions you may have on how to replace board with buzzer. Is it in the same compartment where the timer is located?
1 Answer Hello Debbie. Yes, it is in the same compartment. Just make sure the power is off. Then when you access the inside of the control panel, you should be able to remove the board. It just lifts out of the holder. Read More...
Alan November 08, 2014 for Model Number GTDP400EM2WS The timer will only work in timed setting, not under the cycles. Dryer heats okay but will not shut off automatically. The buzzer works on the dryer control board. Thanks
1 Answer Hello Alan, If the ducting is short, straight, and not restricted, this will be a timer WE4M527, or a board WE04X10103 issue. Read More...
1 Answer Hello. Its sounds like the timer is defective and needs to be replaced. The correct timer for your model is part WE4M370 Read More...
Rich March 23, 2012 for Model Number dpsr610gg5wt Dryer working fine in all settings. Heats up fine in all settings, but only advances to off in time setting. Will not advance in any other settings.
1 Answer Hi Rich. There is a moisture sensor control board part # WE04X10102 that senses the clothes moisture as they pass on the sensor bars under the front lower side of the inner drum lint screen. Look inside the unit and use a scotchbrite to lightly scuff up the bars to remove the fabric softener build up also to give it a fresh start. Thank You. Read More...
Jonathan October 13, 2011 for Model Number DE08-US1 Dryer will run for 5-10 min then cutoff, will restart in a minute or so, replaced safety thermostat still having problem, what do you think is the problem?
1 Answer Hi Johnathon. The motor can overheat and the overload can temporarily open, part # is WE17X10010. The heating element can expand if the vent is clogged, temporarily shorting and opening a safety thermostat. Element part # is WE11M23. If the restring coil is needed then replace it with part # WE11M23. Thank you. Read More...