Marty September 15, 2013 for Model Number PSI23SGRB SV Hi My GE side by side refrigerator(Model:PSI23SGRB SV) is working and cooling. But after running 1 or 2 days, it will be turn off automatically. The LED on refrigerator temp. of Bracket & Ov suddenly become to "OFF". It happened so many times when refrigerator runs after 1 or 2 days. (1) I already checked the main board, there is no any error I think (2) The LED on freezer temp. of Bracket & Ov can NOT show any figures, only "-" Is there any way to fix it? Thanks.
1 Answer Marty, If the display goes blank then at that time check for power from the main control to ensure that it is going to the display board. If it is then the display board is faulty and would need to be replaced. Read More...
Robert August 26, 2013 for Model Number PSC23SGPASS When I attempt to set temp for freezer section or refrigerator section desired temp setting will display for a few seconds then return to warmer or current temp. The refrigerator is now room temp.
1 Answer Robert, If the unit is not cooling ou will want to check to make sure that the compressor is running on the unit. If the compressor is not running but there is a clicking sound every couple of minutes then you would want to replace the overload and relay. The Refrigerator control should show the actual temperature of the unit. If the unit is cooling but not showing the correct temperature then you will want to test the thermistors. Check the resistance of the thermistors which should have values of 42.2K ohms @ 0 degrees, 14.4K at 37 degrees and 5K at 77 degrees. Read More...
Anthony July 06, 2013 for Model Number psc23shrdss My refrigerator developed a problem recently. It goes off on its own, and the display reads off, on both the freezer and the fresh food settings. I can turn it on from selecting more cool, but after a couple hours of working perfectly it stops, and displays off again as if someone turned it off. My food is at risk. how can you help? Anthony
1 Answer Hello Anthony, You need to use a test meter on the wall outlet the unit is plugged into and make sure neutral, hot, and ground are wired correctly. You see, if the polarity is incorrect, the floating voltage on neutral will be interpreted by the control as a command. This can cause the unit to "think" it is being turned off. The other thing you should check is the control on the back side of the touch pad. If ice has been dispensed into a drink and it splashes up onto the control, it can cause all kinds of issues. Read More...
Thomas January 31, 2013 for Model Number HR425129 i have a ge monogram refrigator and the bracket &ov doesnt light up so I can't control the temp sould I replace that part.
1 Answer Hello Thomas, You will want to check for 12vdc coming from the main board. You will check this across connector J4 pins 2 to 3. If no voltage then replace main board. If voltage replace user interface. Read More...
Eugene D. August 28, 2012 for Model Number PSI23SGRBSV There has been frost developing on the ice maker exit going to the ice dispenser which every now and then blocks the flow of ice. I would take off the frost adjust the freezer temperature to 0 degrees every time I find the reading go to -1 or -2 degrees but could not get rid of the problem. After about a month, the display of the freezer temperature went out on the refrigerator digital temperature display. Meat stored in the freezer started getting soft. I could still feel cooling in the freezer but not enough to freeze meat kept inside. What could be the problem? Thanks for your answer..
1 Answer Hello Eugene, The frost is moisture condensing in the ice chute. The ice door has an air leak as this is what causes this complaint. You should first use a flashlight, shining it from the front and look in to the ice chute. This will show you where the leak is. If light can pass, so can air. There are several things which can cause this ranging from a bad seal around the ice door, a broken or mis-aligned linkage, and the actuator 241689301 can actually gather enough condensation to rust and seize the plunger so complete travel is restricted or prevented completely. You should remove the dispense cover to check the components. An air leak will allow cold air to leave the unit and will introduce room temperature air which will affect the interior temperature. Read More...
Tony Gomez May 16, 2011 for Model Number psc23nswass The turbo cool doesn't work. And the refrigerator side doesn't cool properly. What can I do?
1 Answer Hello Tony. Here is a link to our Repair Forum, this is a free service to our customers. Use this link to access the repair for your question. Hope this helps. http://forum.appliancepartspros.com/refrigerator-freezer-repair/4221-freezer-fine-refrigerator-too-warm.html Read More...