Tom September 02, 2015 Trying to install WB27T10230. The wiring is different than OE. I read the previous questions. There are two whites on the OE I connected the blue and yellow and a connection in front of the blue on the broil relay is open as well as one to the right of the blue and one on the board. Not sure where last three wires go
1 Answer Hello Tom. We will need your model number to help you with this. Please call 1-877-477-7278 or post your model number with a new question on the parts page. Here is a link to help you locate it. http://www.appliancepartspros.com/modelnumber_locator.aspx Read More...
Robert October 19, 2013 for Model Number JBP78A44AA Replacing the control panel. The old panel has labeled lugs Bake (yellow wire), Broil (blue wire), a double clipped white wire going to the N lug, a double wired single clip red wire to the Line lug. All are on the board. So 4 lug/clip connections. The new panel (Part # WB2710230) has two transformers with the lugs on the transformers.One with a yellow dot (bake) lug and a COM lug. The other has a purple dot (broil )lug, a COM lug and an NC lug. It also has the N (AC N) lug on the board. This is a total of a 6 lugs. I assume the red double needs to be split and run to the COM lugs. Just don't know about the NC lug on the broil transformer.
1 Answer Robert, The yellow bake will go to the com on the relay where the yellow dot is. The broil will go to the com on the purple dot relay with the double red going to the NC on the purple relay. The white will go to the N on the new board. Read More...
Mike August 17, 2013 for Model Number JBP26GS1 General Electric WB27T10230 Control Panel schematic is slightly different from the old part. Can you tell me where the blue, white, red and yellow wires fit into the back of the new Control Panel part?
1 Answer Mike, The Red wire for the unit will go to L1, White will go to N, Yellow goes to the bake relay which has the yellow dot, and Blue will go to the broil relay which has the purple dot. Read More...