Tim January 15, 2015 for Model Number GE dcvh680ej My GE dryer is about 4 years old now. The problem is that some of the clothes I have been drying will dry normally at a little above normal time. When I put a load of about 8-10 towels, it will take about 3 complete cycles to dry. I have just replaced the heater and it turns bright orange after about 30 seconds. It does produce heat, but refuses to dry the clothes. I have cleaned dryer thoroughly of all lint. I have no idea what sensor to replace next. Such a price difference, want to eliminate replacing all sensors if possible... Thanks in advance.
1 Answer Tim, You will want to check the venting to the outside of your home. If the venting is clogged or restricted it will cause for the unit to have much longer drying times. This normally will happen on towels or cottons that it is more noticeable but that is what you will want to check. Read More...
A Pat June 12, 2013 for Model Number GE dryer model: DCVH515GF1WW GE gas dryer stopped working and found that the belt was broken. When I press start the dryer control panel comes on normally and then hitting start the timer starts to count down quickly by seconds instead of minutes and nothing else happens... no clicks or motor sounds or anything. Replaced belt but still results in the same exact issue.. Checked the switch that detects if the belt is broken and that is engaging and showing as good. Door switch is also good. Check all thermostats for 0 resistance/continuity and all look good except for Inlet Control Thermostat... is that supposed to show continuity? Shorted the wires connected to the inlet control thermostat but no difference... Any ideas? what else could it be? Please help.
1 Answer A Pat, Based on this information it sounds like the control board for your unit is defective and would need to be replaced. Read More...
Ted May 30, 2013 for Model Number Dbvh512gfoww Hi my dryer ignites runs for awhile then shuts down. I change solenoids still has the problem. Checked continuity the only thing that reads open is the Inlet control thermostat I don't know if it should.
1 Answer Ted, The inlet control thermostat should read open as it is inline with the igniter and gas valve. Read More...
Chip October 03, 2012 for Model Number DCVH660GH0BB The dryer burners come on and then turn off after about 5 minutes. The dryer continues to run and cloths do not get dry. What do I need to replace?
1 Answer Hello Chip. Based on the information you provided, the coils 279834 are bad and need to be replaced on the unit. Read More...
Greg Here Again September 10, 2012 for Model Number dcvh660eh0bb I appreciate all you help so far...I have found that all of the thermostats are working properly and the inlet control thermis is ok... I replaced the main power board... checked the door switch...vaccuumed the inside of the cabinet and motor housings...pristine condition now... checked the thermostat on the motor also..all good... what now? How do I check out the motor it cant be anything else ... oh yes...I am getting 120 at each leg...so power is ok also...help again!
1 Answer Hello Greg. Unplug the heater and test both wires for power. One of the wires will be dead. You need to trace that wire and see where you are loosing the voltage at and replace that part. Be careful as you are dealing with live power there. Read More...
Greg September 05, 2012 for Model Number dcvh660Eh0bb My resistance shows 97.4.... the other thermal fuses show continuity... where do I go from here... nothing but the front panel lights work... where do I go from here... out of a dryer for a week and a half...this shouldnt be this hard... but alas..!!! lol Help.. :)
1 Answer Hello Greg. Check and make sure you have 240 volts coming to the dryer. Check and make sure the unit is not set to Air Fluff. Also check the heater and thermostats and see if they are good. If all is good, then either the motor or the main power board WE4M488 is bad and will need to be replaced on the unit. You can test these with a multi-meter MA-DM1. They should read closed for continuity. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Greg August 31, 2012 for Model Number dcvh660Eh0bb I have checked for continuity in each fuse, no continuity in this inlet control thermis, replaced it with a new one and no continuity with the new one either. This sucks...Help!
1 Answer Hello Greg. The thermistor should not show continuity, but should show resistance in the unit. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Daniel July 21, 2012 for Model Number General Electric DCVH515GF1WW Gas dryer Hi, My dryer doesnt heat up anymore. First you hear the ignitor coming on and the heat comes out of the exhaust, but then cools after a few seconds. Ive tested the coils at 2000k and reads anywhere from 2.0 to .5 on the dual and 1.4 on the main. Im understanding from all the research ive done that refers to as closed. Can you confirm is this is a good reading please. Also Ive noticed my inlet control thermis is reading 97.5 is this normal and what is this part designed to do? Is this part related to my no heat situation?
1 Answer Hello Daniel. Based on the information you provided, it sounds like the coils are failing on the unit and will need to be replaced. You will need to replace both coils WE4X692 and WE4X693 on the unit. Read More...
1 Answer Hey Ralph, This part should read closed for continuity on a multi-meter MA-DM1. Hope this helps. Read More...