Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Inlet Control Thermistor by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM12927561
Manufacturer Part Number: WE4M398

The Inlet Control Thermistor is an OEM part for GE dryers. It monitors and regulates the temperature of the incoming air to ensure optimal drying performance. This thermistor sends temperature readings to the dryer's control board, which adjusts the heating element accordingly to maintain the desired temperature throughout the drying cycle.

You should replace this inlet control thermistor if it becomes faulty or fails to provide accurate temperature readings. Common causes of a bad thermistor include electrical failures, damage from overheating, or wear and tear from regular use.

Symptoms of a bad inlet control thermistor include:

  • Dryer not heating properly
  • Overheating or uneven drying
  • Dryer shutting off prematurely
  • Error codes related to temperature issues

This GE replacement part is also compatible with Hotpoint, RCA, and some Kenmore models.

More
$44.66

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Ge Inlet Control Thermistor (Part Number: OEM12927561)

1 Answer

Glen, We would expect a resistance of 9 to 10 K ohms at room temperature, all thermistors should have a minimum resistance and shouldn't have a closed or open circuit, unless it's faulty, you'll need to recheck the resistance. It sounds more like the heater relay for the inner element on the control board or the inner element has failed.

Read More...
Nacho for Model Number DCVH680GJ2WW

dryer runs but does not heat up. i checked all components for resistances with multimeter. All either gave a numeric reading or I heard an audible sound on the meter. The only one that did not do either was the Inlet Control Thermistor, located on the rear heat diffuser. Could this componrny cause the dryer igniter, flame senor from operating? Forgot to mention I did replace the two coils on the gas valve since this was the most common components that fail.

1 Answer

Nacho, All the thermostats should have a "closed" circuit at room temperature when tested with multi meter. Thermistors have a "preset" resistance reading at room temperature ( on your machine the thermistor should read 75 to 85K ohms), The resistance will change when the temperature increases or decreases, depending on the coefficients of the thermistor. In your case, the inlet control thermistor is faulty. This would interrupt the voltage to the gas valve and the dryer will not heat. (make sure you remove the wires from the thermostat and thermistor terminals when testing). Thanks,

Read More...

1 Answer

Luis, Disconnect the wires from the thermistor and place your meter leads across the terminals, you should read 98 to 102 K ohms resistance at room temp. (77 dgrs. F.) If there is no resistance, or the resistance reading is incorrect, then the thermistor is faulty and will need to be replaced. Thanks,

Read More...

1 Answer

Dustin,

There are 2 components other than the thermostats which would cause the heating element not to work. First is the motor and second the Control board. The best option is to disconnect the power to the unit and access the heating element. Disconnect one wire that is going to the heating element, preferably the one on the thermostat side. Plug the unit back up and using a multimeter you will want to turn the dryer on and test for 120 vac at the terminal on the heater where the wire was disconnected. What this will do is eliminate the heater element itself and the motor. If there is 120 vac at this point then you know the heater is good and the motor is good because the other 120 vac coming through the thermostats is the control board side of the circuit. If there is not 120 vac at that point then you will want to test the other terminal on the heater and check for 120 vac. If there is not 120 vac then the motor would be bad .

Read More...
Dan for Model Number dcvh660eh0bb

We have a GE dcvh660eh0bb electric dryer. A couple weeks ago we noticed the dryer would sometimes stop mid-cycle and we would have to restart it to finish the load. Yesterday we were drying a load and it stopped and wouldn't power back on. We happened to be near it when it did it this time and noticed it was extremely hot. You couldn't keep your hand on the top of the dryer for more than 2 or 3 seconds. We unplugged it for a bit then plugged it back in and it powered back on but didn't want to attempt to dry a load without figuring out what the problem was first. Any suggestions?

1 Answer

Dan,

The most likely cause for this issue would be that the thermal fuse on the blower housing has failed and would need replaced. Also check to make sure that the venting is clean from the blower wheel to the outside of your home.

Read More...

1 Answer

Hello RT. If the unit is heating, It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly.

Read More...

1 Answer

Howard,

The thermistor will get lower in resistance as the temperature gets higher. The inlet control should not read a open circuit but will have resistance reading. You can check the tech sheet in the unit to see what the resistance values should be.

Read More...
Tim for Model Number DCVH680EJ1WW

My GE dryer is about 4 years old now and recently I noticed that clothes weren't drying. I replaced the heater element and no help. I cleaned the lint trap area very thoroughly and while I was down at eye level with the drum, I started the dryer and after about 10 seconds, the heater came on and turned orange. About 3-5 seconds later, I heard a click and then the heater shut down.. Can you tell me what sensor went bad. With the price difference of all the sensors, I need to know if I have another problem other than a bad sensor.

1 Answer

Tim, You may not need parts at all. Your first step should be to disconnect the exhaust vent from the back of the dryer and check the vent system and hood for links, clogs and blockages. If you have a clogged or restricted vent system, the air flow in the dryer drum is disrupted and the excess heat causes the hi limit switch to open and shut the element off, early.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!