Glen April 30, 2017 for Model Number PCVH640EJOWW I have no continuity in the inlet control thermistor is it any good and will this stop the inside element from working only the outer element gets red
1 Answer Glen, We would expect a resistance of 9 to 10 K ohms at room temperature, all thermistors should have a minimum resistance and shouldn't have a closed or open circuit, unless it's faulty, you'll need to recheck the resistance. It sounds more like the heater relay for the inner element on the control board or the inner element has failed. Read More...
Nacho April 13, 2017 for Model Number DCVH680GJ2WW dryer runs but does not heat up. i checked all components for resistances with multimeter. All either gave a numeric reading or I heard an audible sound on the meter. The only one that did not do either was the Inlet Control Thermistor, located on the rear heat diffuser. Could this componrny cause the dryer igniter, flame senor from operating? Forgot to mention I did replace the two coils on the gas valve since this was the most common components that fail.
1 Answer Nacho, All the thermostats should have a "closed" circuit at room temperature when tested with multi meter. Thermistors have a "preset" resistance reading at room temperature ( on your machine the thermistor should read 75 to 85K ohms), The resistance will change when the temperature increases or decreases, depending on the coefficients of the thermistor. In your case, the inlet control thermistor is faulty. This would interrupt the voltage to the gas valve and the dryer will not heat. (make sure you remove the wires from the thermostat and thermistor terminals when testing). Thanks, Read More...
Luis Santa Cruz April 01, 2017 for Model Number G.E\DCVH515EF0WW electric dryer How to test this sensor?? ,in the schematic has the number 506. In the front of the sensor shows 100k...omhs??It should be?? because it has no continuity.
1 Answer Luis, Disconnect the wires from the thermistor and place your meter leads across the terminals, you should read 98 to 102 K ohms resistance at room temp. (77 dgrs. F.) If there is no resistance, or the resistance reading is incorrect, then the thermistor is faulty and will need to be replaced. Thanks, Read More...
Dustin March 10, 2017 for Model Number gtds560ef4ws My dryer element get hot for about 10 seconds and then shuts off and doesn't come back on. The dryer continues to spin and everything else runs fine but it wont get hot. I checked all the thermistors for continuity and they passed the test. Any idea what the issue might be?
1 Answer Dustin, There are 2 components other than the thermostats which would cause the heating element not to work. First is the motor and second the Control board. The best option is to disconnect the power to the unit and access the heating element. Disconnect one wire that is going to the heating element, preferably the one on the thermostat side. Plug the unit back up and using a multimeter you will want to turn the dryer on and test for 120 vac at the terminal on the heater where the wire was disconnected. What this will do is eliminate the heater element itself and the motor. If there is 120 vac at this point then you know the heater is good and the motor is good because the other 120 vac coming through the thermostats is the control board side of the circuit. If there is not 120 vac at that point then you will want to test the other terminal on the heater and check for 120 vac. If there is not 120 vac then the motor would be bad . Read More...
Dan February 26, 2017 for Model Number dcvh660eh0bb We have a GE dcvh660eh0bb electric dryer. A couple weeks ago we noticed the dryer would sometimes stop mid-cycle and we would have to restart it to finish the load. Yesterday we were drying a load and it stopped and wouldn't power back on. We happened to be near it when it did it this time and noticed it was extremely hot. You couldn't keep your hand on the top of the dryer for more than 2 or 3 seconds. We unplugged it for a bit then plugged it back in and it powered back on but didn't want to attempt to dry a load without figuring out what the problem was first. Any suggestions?
1 Answer Dan, The most likely cause for this issue would be that the thermal fuse on the blower housing has failed and would need replaced. Also check to make sure that the venting is clean from the blower wheel to the outside of your home. Read More...
Lynn October 16, 2016 for Model Number DQSR483EE1WW The dryer shuts off mid cycle and sometimes won't start back up for up to an hour, I have cleaned the exhaust line thoroughly and seem to have good airflow. What do you suggest?
1 Answer Hello Lynn. Based on the information you provided, you will need to order and replace the motor kit WE17X10010 on the unit. Read More...
Brent July 05, 2016 for Model Number LG4634EQ1 My whirlpool gas dryer (model LG4634EQ1) starts and gets hot right away. After about 5 minutes, the dryer turns itself off and won't start again until it has cooled off. I already replaced the thermal fuse and cycling thermostat. Is there anything else I can replace that might fix this problem?
Rt March 18, 2016 for Model Number DPSE810EG5WT GE Profile DPSE810EG5WT Dryer; recently our dryer hasn't been drying our clothes properly. They seem to be slightly damp.
1 Answer Hello RT. If the unit is heating, It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly. Read More...
Howard March 28, 2015 for Model Number GE PROFILE ELECTRIC DRYER PN 559C259G05 Does it close when it gets hot? It measures 75k ohms at room temp.
1 Answer Howard, The thermistor will get lower in resistance as the temperature gets higher. The inlet control should not read a open circuit but will have resistance reading. You can check the tech sheet in the unit to see what the resistance values should be. Read More...
Tim January 20, 2015 for Model Number DCVH680EJ1WW My GE dryer is about 4 years old now and recently I noticed that clothes weren't drying. I replaced the heater element and no help. I cleaned the lint trap area very thoroughly and while I was down at eye level with the drum, I started the dryer and after about 10 seconds, the heater came on and turned orange. About 3-5 seconds later, I heard a click and then the heater shut down.. Can you tell me what sensor went bad. With the price difference of all the sensors, I need to know if I have another problem other than a bad sensor.
1 Answer Tim, You may not need parts at all. Your first step should be to disconnect the exhaust vent from the back of the dryer and check the vent system and hood for links, clogs and blockages. If you have a clogged or restricted vent system, the air flow in the dryer drum is disrupted and the excess heat causes the hi limit switch to open and shut the element off, early. Read More...