For Ge Refrigerator Main Control Board_Core (Part Number: OEM24241332)

David for Model Number GFD28GSLCSS

I purchased this refrigerator new almost 6 years ago. Recently the door mounted water dispenser began freezing up. I gained access to the evaporator and discovered it to be heavily frosted up. The evaporator fan is working.Resistance through the defrost heating element is 83.5 Ohms.Continuity through the thermostat switch is 0.1 Ohms.I couldn't access the thermistor harness to measure its resistance ( the pigtail appears to be potted in the insulation of the refrigerator) I verified that there is a good ground through the harness connector. I was unable to detect any AC voltage at the harness connector. Is there technical data / wiring schematic available to help troubleshoot this issue?

1 Answer

David,

There is not a tech sheet that will tell how to troubleshoot but the resistance of the heater and the continuity on the thermostat does sound good. For testing the resistance, you can test at the main control board on the J10 connector, test from pin 3 Brown/pink to Pin 4 Pink/brown. While sitting in the ice on the evaporator it should have a resistance of approximately 36.4K ohms of resistance. If the thermistor checks ok then this will be a faulty control board.

Read More...
Dan for Model Number GFE29HMEEES

So I compressor is running, and shutting off automatically, seems to be cooling in frig and freezer is working, but have no lights inside frig, and front control is dead. I have unplugged and tried to reset, and inspected control in the back of the frig...it has a green flashing light. I assume that either the back or the front control panel is bad. How do I know which one. I have part number wx55x38248 for the back, and wr55x11144 for the front. just not sure which one to order.

1 Answer

Dan,
It sounds like your unit has been placed into Sabbath Mode. The Sabbath Mode will turn off interior lights, temperature control, and advanced features. The compressor will run on a timed defrost when in Sabbath mode. To enter/exit Sabbath mode, press and hold the lock and light buttons simultaneously for 3 seconds.

Read More...
Ryan for Model Number GFE28GSKJSS

Interior LED lights are dim. Followed this guidance: https://www.appliancepartspros.com/diy-story-ge-model-gfe28gskjss-refrigerator-pin-point-led-diy5053015.html Each of the five interior lights measure 2.5 volts so seem good, but the board at J14 with door open measured like 27 volts (or so). I ordered new board and installed. Same exact symptoms. New board also measures somthing like 27 V at J14 connector. Did I just get really unlucky and get a bad board (and so should return and try again)? or Is that guidance wrong and is there something else to try? thanks very much.

1 Answer

Ryan,
Try unplugging the J14 connector and see what the voltage supply is with the doors open. If your supply voltage returns to normal then there is a fault in the wiring or a light.

Read More...
Bruce for Model Number GFE28HGHBBB

In the fresh food section, the compartment fails to stay cold because the evaporator coils are iced up. The thermistor, temperature thermostat, and fan have been replaced. The defrost heater shows continuity on an ohmn meter and reads approximately 80 ohmns resistance, so I believe the heater is good. Am I down to replacing the main board? Each time a part was replaced, and the fridge was defrosted and restarted it cooled fine for a couple weeks before icing back up. On another note, I can't seem to get it to go into the diagnostic mode anymore. I have entered this in the past. Could this be a symptom of a bad main board as well? Thanks for any help on this.

1 Answer

Bruce,
For a defrost issue, if the defrost thermostat/thermistor and the heater are good. The issue would be a timer/control board. Yes, not going into diagnostics would be a symptom of a board issue.

Read More...
Jamie for Model Number PYE22KSKKSS

I have a GE Profile that was 3 years old and it died completely. I had the mother board replaced *** though I think it was just a general GE motherboard and not the one for the discontinued GE Profile. Q: Is this going to be just the beginning of the end? I mean wIll things continue to burn out...and be faulty - or should I just buy a new fridge. I don't have the energy to have things constantly go wrong. Right now the fan blade is making a horrible noise randomly because of ice build up.

1 Answer

Jamie,

If the unit is repaired properly then it should work good for you. You will want to make sure that the correct control board was put into the unit which should be part number WR55X46805C.

Read More...
Ed for Model Number GNE29GMHDES Refrigerator

I have a GE refrigerator with with 5 LED barely on. I am getting 28VDC between J14-7 and J14-6 on the control board (direct feed to the LEDs). All other features of the fridge work fine. I have replaced ALL 5 LEDs with new ones. I even tested each individually with a 9V battery and they all turned on very brightly. If there was a open somewhere between J14-7 and J14-6 on the LED circuit, the LEDs would not even come on, but they do-- yet they are all very dim. Any suggestions or thoughts as to what may be going on?

1 Answer

Hello Ed, usually this problem is due to a failing LED light however with all new LEDs that would not be the case, if the 28vdc from the main board drops with the lights being powered then it may be a problem with the LED power circuit in the main board if the 28vdc only drops slightly then there may be a wiring problem in the LED light circuit in the ref cabinet as they are connected in series, each LED light runs on about 5vdc.

Read More...

1 Answer

Michael,

There are a couple of checks you can make. On the J5 connector at the board at the top of the door, check from pin 1 White Wire to pin 2 Red/orange wire for 5VDC Then you can test the J3 connector Pin 6 White/Red to J3 pin 18 Blue/Green for the ice arm which should be 12 vdc, J3 pin 11 White/Black to J3 Pin 18 for the rake and J3 pin 14 Black/Red to J3 pin 18 for sensor. You can also test the rake motor for 2.9K ohms at connector J4 Pin 2 Purple to J4 Pin 16 Orange. The J4 Pin 9 Aqua to J4 Pin 16 For the ice mold heater and test it for 110ohms.

Read More...

1 Answer

Jim, the wires at the door hinge would need to be inspected for any indications of breaking. From there, the user control board would need to be tested for 12VDC from the blue wire at connection J1 pin 1 to the black/pink wire at connection J1 pin 5. There should also be a -12VDC (12VDC if negative readings not available on meter) from the blue wire to the red/black wire at pin 3. If the voltage is present, the user control board WR55X39248 has failed.

Read More...

1 Answer

Jim, This is likely a main board failure. The green light indicates the unit has power but there appears to be no output to any other system.

Read More...

1 Answer

Zo,

With the defrost heater, thermistor and thermostat being good then this will be a main control board issue.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google