Customer Questions and Answers for Refrigerator Main Control Board_Core by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM24241332
Manufacturer Part Number: WR55X46805C
$261.17

IN STOCK
Ships Monday Guaranteed
Add to Cart

Questions & Answers

For Ge Refrigerator Main Control Board_Core (Part Number: OEM24241332)

1 Answer

BDS, thanks for the question.
The condenser fan should receive 13.6VDC from the main board on J9-1 to J9-2. If you have it at this point on the main board, check the wiring from the board to the fan motor. If you don't have this voltage from the main board when the compressor and fan should be running, you'll need to replace the main board.

Read More...
Christopher for Model Number GNE29GMHBES

The fridge compartment is not reaching the set point. I replaced the evap cover, air tower, and evap fan. When I first replaced the fan, it seemed to be pushing much more air than it does now. Is that an indication of a failed control board, or is the evaporator frosting up too much because of a failed defrost sensor? I am about to replace the defrost sensor and the refrigerator temperature sensor and see if it helps. Any input would be greatly appreciated.

1 Answer

Yes the failed defrost sensor would be my prime suspect, If the defrost system isn't working properly, ice and frost accumulate on the evaporator coils causing a decrease in air flow to the fridge

Read More...

1 Answer

Betsy,

It would be recommended to check and make sure that the thermistor is good. If the thermistor is not good then it would need to be replaced. If the thermistor is good then replace the control board.

Read More...

1 Answer

Hello Jude, thank you for choosing AppliancePartsPros.com. There is an LED for the Pantry drawer that would have a wire connection on the left side. If the harness coming from the wall was scraped and exposed any wire, it could have created an electrical short. The wire harness would need to be inspected for any signs of damage when the appliance power supply cord is unplugged. If it is damaged, unfortunately, it is not a replaceable part due to it being foamed into the liner of the appliance. It is likely that the flash was an electrical short, which could also result in damage to the main control WR55X46805C or the LEDs WR55X25754.

Read More...

1 Answer

Allan,

Check at the J3 connector on the display board to make sure that there is 13.6 VDC between the black/pink wire to the red/black wire. If there is proper voltage but the dispenser is not lighting up then this will be a faulty dispenser board that would need to be replaced.

Read More...

1 Answer

Ryan,

Thank you for your question. With the fan ramping up and down, this would most likely be a control board issue in which you would need part number WR55X46805C.

Read More...

1 Answer

Melissa,
I recommend using the tech sheet that came packaged with your refrigerator to run the diagnostics and check for error codes.

Read More...

1 Answer

Hello Juan, thank you for contacting Appliance Parts Pros.
If you can hear the valves activating or can verify voltage to the valves when calling for water then I would suspect an issue with the Filter Manifold [WR02X13684].

Read More...

1 Answer

Will, if there is no voltage going to the defrost heater when a forced defrost is activated in the diagnostic mode, the failure would most likely be caused by the main control WR55X46805C.

Read More...

1 Answer

Hello Mark, thank you for contacting APP,

If the Condenser Fan is still not running after being replaced but everything else is working properly, it would appear that you have a failed Main Control WR55X46805C. The only other possibility is the non-serviceable wiring harness that runs through the cabinet from the control to the harness for the condenser fan, and if this were damaged the control would be getting mixed signals and showing symptoms of other issues. I would recommend replacing the Main Control.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google