Bds October 20, 2026 for Model Number GFE28GSKMSS compressor fan was not working, replaced it but it is not powering on. voltage meter shows no power thru the cables. could it be the main control board needs replacing?
1 Answer BDS, thanks for the question.The condenser fan should receive 13.6VDC from the main board on J9-1 to J9-2. If you have it at this point on the main board, check the wiring from the board to the fan motor. If you don't have this voltage from the main board when the compressor and fan should be running, you'll need to replace the main board. Read More...
Christopher October 12, 2026 for Model Number GNE29GMHBES The fridge compartment is not reaching the set point. I replaced the evap cover, air tower, and evap fan. When I first replaced the fan, it seemed to be pushing much more air than it does now. Is that an indication of a failed control board, or is the evaporator frosting up too much because of a failed defrost sensor? I am about to replace the defrost sensor and the refrigerator temperature sensor and see if it helps. Any input would be greatly appreciated.
1 Answer Yes the failed defrost sensor would be my prime suspect, If the defrost system isn't working properly, ice and frost accumulate on the evaporator coils causing a decrease in air flow to the fridge Read More...
Betsy August 18, 2026 for Model Number CYE22TSHQSS The temperature in the refrigerator section vacillates from 22 - 32 degrees, even though the control panel says that it is 37. It is making ice, the freezer is fine. We have replaced both fans, did a full defrost (unplugged) and replaced the temperature sensor behind the lower drawers. Is this a control board issue?
1 Answer Betsy, It would be recommended to check and make sure that the thermistor is good. If the thermistor is not good then it would need to be replaced. If the thermistor is good then replace the control board. Read More...
Jude July 21, 2026 for Model Number GE Profile GNE29GSKGSS When I was replacing the evap fan I had to remove all drawers. When replacing the lower left drawer holder there was a flash and all refrigerator leds went out.evrything else is normal. I saw a wire with a plug that comes out of the wall next to the drawer . I never saw it before .It is just a bare plug. I feel it must have something to do with the lights not working . I see no part the should plug into it
1 Answer Hello Jude, thank you for choosing AppliancePartsPros.com. There is an LED for the Pantry drawer that would have a wire connection on the left side. If the harness coming from the wall was scraped and exposed any wire, it could have created an electrical short. The wire harness would need to be inspected for any signs of damage when the appliance power supply cord is unplugged. If it is damaged, unfortunately, it is not a replaceable part due to it being foamed into the liner of the appliance. It is likely that the flash was an electrical short, which could also result in damage to the main control WR55X46805C or the LEDs WR55X25754. Read More...
Allan January 04, 2026 for Model Number GYE22HSKSS My control panel has stopped functioning but the refigerator/freezer is operating. The lights do not come on and cold water and ice functions do not work. I've unplugged/plugged the unit with no response from the control panel. Is there a way to bring the control panel back to life?
1 Answer Allan, Check at the J3 connector on the display board to make sure that there is 13.6 VDC between the black/pink wire to the red/black wire. If there is proper voltage but the dispenser is not lighting up then this will be a faulty dispenser board that would need to be replaced. Read More...
Ryan July 28, 2025 for Model Number GFE28GSKISS The evaporator fan constantly revs up and down while activated. Is this most likely a main control board issue or how do I diagnose the issue?
1 Answer Ryan, Thank you for your question. With the fan ramping up and down, this would most likely be a control board issue in which you would need part number WR55X46805C. Read More...
Melissa March 11, 2025 for Model Number GE GFD28GELBDS Fridge is set for 34 degrees but will fluctuate from 34 to 40 up to 50 and then back down again. We have already cleaned the coils, cleared the drain, replaced the evaporator & condenser fans, door seals, capacitor, overload/relay, defrost thermostat and temp sensor. What else could it possibly be?
1 Answer Melissa,I recommend using the tech sheet that came packaged with your refrigerator to run the diagnostics and check for error codes. Read More...
Juan January 02, 2025 for Model Number GFE27GMDFES So I had replaced the inlet water valve, the dual valve at the ice and water dispenser and the main board. I am still not getting any water to pump up through the system. Is there something I am missing again that I have not checked? The Main Board was the last part I was going to replace as it was $300. I am stumped now.
1 Answer Hello Juan, thank you for contacting Appliance Parts Pros.If you can hear the valves activating or can verify voltage to the valves when calling for water then I would suspect an issue with the Filter Manifold [WR02X13684]. Read More...
Will August 09, 2024 for Model Number GFE26GSKFSS I purchased and installed a new refridgerator defrost heater and harness. I am not getting power when i plug harness in. not reading any volts with multi meter but the one that runs the fresh food condensor fan does have power. I assuming this is a bad control board?
1 Answer Will, if there is no voltage going to the defrost heater when a forced defrost is activated in the diagnostic mode, the failure would most likely be caused by the main control WR55X46805C. Read More...
Mark July 13, 2024 for Model Number GFE27GMDFES I have a GE side by side with board WR55X38248 My condenser fan does not run and the refrigerator does not achieve the set point temperatures. I've replaced the fan and it still doesn't work. How can I test the control board?
1 Answer Hello Mark, thank you for contacting APP,If the Condenser Fan is still not running after being replaced but everything else is working properly, it would appear that you have a failed Main Control WR55X46805C. The only other possibility is the non-serviceable wiring harness that runs through the cabinet from the control to the harness for the condenser fan, and if this were damaged the control would be getting mixed signals and showing symptoms of other issues. I would recommend replacing the Main Control. Read More...