Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Refrigerator Main Control Board_Core by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM24241332
Manufacturer Part Number: WR55X46805C
$261.17

IN STOCK
Ships Monday Guaranteed
Add to Cart

Questions & Answers

For Ge Refrigerator Main Control Board_Core (Part Number: OEM24241332)

1 Answer

ED,
If you have 14 VDC at the fan motor then the fan motor itself would need to be replaced. WR60X26866 No update will be needed to the control when this part is ordered.

Read More...
Adam for Model Number PFE28KSKBSS

Hi, for the indicated model, I am having a persistent issue. There is ice and frost build-up in the freezer section, and I have tried a variety of remedies. Initially noticed freezer door not closing all the way. I disassembled to inspect and found ice build-up on the bottom of the freezer. I removed it, and then removed the evaporator cover and found ice buildup below the evaporator cover and in the drain (the evaporator was not iced over). I melted everything, cleared the drain, and replaced the check valve and the drain tube, only for the problem to return and get worse. I then noticed frost build-up in the freezer, as well as the above issues. I removed all the ice, checked all of the thermistors in the freezer and the fridge, and replaced the freezer evaporator thermistor, the defrost heater and harness, the overtemperature thermostat, and the freezer door seal. Non seemed to be malfunctioning, but they were cheap, and easy to replace, so I gave it a try. I also melted all ice, including in the drain The evaporator fan and the icebox fan are working. The problem has returned within five days. The refrigerator portion seems to be working as it should and maintaining good temperature. I have disassembled to check everything there, and everything seems to be in good working order. I can only think it is a control board issue at this point, but I have no idea how to tell or test it. Do you have any suggestions?

1 Answer

Adam, it would be recommended that the freezer door is checked all the way around to ensure it is making a proper seal against the freezer cabin. If it is, there would likely be a failed control WR55X46805C as identified through the process of elimination. However, if the ice is accumulating on the side walls of the freezer, this would be an indicator of an air leak.

Read More...

1 Answer

Canada,
Two voltages to the inverter are needed. 120 VAC and your low voltage DC current. The compressor reads okay so as long as you have voltage to the inverter then that is the part that needs replaced.

Read More...

1 Answer

RGD,

You will want to test to make sure that there is 12 vdc going from the main control board to the lights and if there is not proper power then this will be a faulty main control board.

Read More...

1 Answer

Keith, you should first check the heater for voltage and resistance. On the Door Board (located on the top of door) check connector J3 pin 4 to pin 20. Resistance should be about 24.7ohm and the heater operates on 12vdc. If there is no voltage replace the Door Board part number WR55X44126. If the resistance is bad replace the door mullion part number WR17X13240.

Read More...

1 Answer

Rudy,
The refrigerator section has its own evaporator, you need to check and see if ice is forming on the rear wall in that section indicating a defrost issue. Also, it could simply be that you need to clean your evaporator coils which are located by the compressor. Let us know what you find and we will be glad to walk you through it. You will need to repost with all info again.

Read More...

1 Answer

Scott, based on the information provided, the main control WR55X46805C has a short between the terminals located at connection J4 pin 4 to connection J3 pin 3. With the refrigerator unplugged, this can be tested for continuity to verify that there is a shorted connection. If there is continuity between the two points with one of the wire connectors removed, the main control has failed.

Read More...

1 Answer

Lance, I would suspect the main control located on the back of the refrigerator has failed. Part number is WR55X46805C. It controls most of the functions of the entire unit, including the compressor.

Read More...
Kristen for Model Number GE PWE23KSKSS

Our 3-year-old GE Profile™ Series ENERGY STAR® 23.1 Cu. Ft. Counter-Depth French-Door Refrigerator (model #PWE23KSKSS) is cooling normally but the interior lights are all constantly flashing when the doors are open in the refrigerator. I tried a hard reset at the circuit breaker without any luck. Can you please take your best guess as to what the problem might be and if this is a repair that an average person can do or if it requires a professional? Thank you!

1 Answer

Kristen, either a shorted LED or the main control could cause this failure. The main control can be tested for voltage output at connection J14 from pin 7 white wire (with the red probe of a meter) to pin 6 tan wire (with the black probe of a meter). If there is 12VDC being measured continuously with the door open, the failure would be in one of the LEDs and each LED WR55X11132 would need to be tested. If there is not a constant 12VDC, then the main control WR55X46805C has failed.