Eric April 13, 2020 for Model Number PFCF1RKZABB Hi there, Last night my electricity went out. This morning when I got up, I saw that my GE Profile refrigerator was not working...at all. No lights, fans, or any sounds, whatsoever. I checked the fuse box...all was well. I checked all of the GCFI outlets and reset all of them. Nothing worked on the refrigerator. Other than the mother board being fried from a power surge, can you think of anything else I should check? Thanks so much for your help. I look forward to hearing from you! Eric
1 Answer Eric,Based on the information provided check as best as you can for no other shorts, then replace the shorted board and check the operation. WR55X11098C Read More...
Walter January 15, 2020 for Model Number GNE29GSHDSS, main board WR55X30906 Condenser fan not working and compressor gets very hot. I would like to test the main board with a multi meter to see if the board is bad or just the fan. Can you walk me through this procedure?
1 Answer Walter, the main control would be tested for DC voltage at connection J9 pin 1 (with red probe of meter) to pin 2 (with black probe of meter). The voltage reading should be 12VDC. If there is 12VDC, then the red probe would need to be moved to pin 3 and it should read 0 or 5VDC indicating that the condenser fan motor WR60X23363 has failed. Read More...
Brad October 09, 2019 for Model Number GFE28HSHDSS My refrigerator has dual icemakers. The top ice maker and water dispenser stopped working. The freezer ice maker works fine. The paddle for dispenser when depressed does turn the dispenser light on and off. On the display when you depress the icemaker function only the ( ice bottom on or off ) displays. The ( ice top on or off) never displays. I have checked the wire harness at the top of the door.
1 Answer Brad, based on the information provided there would be a communication issue with the door board WR55X44126. The door board can be tested for a signal from the dispenser board when the dispenser paddle is pressed by testing from connection J3 pin 12 with red probe to J3 pin 20 with the black probe of a meter. When the paddle is pressed in, there should be a positive DC voltage reading. If there is, then the door board is not properly operating. The ice maker can also be tested from the board by testing from connection J5 pin 2 and then 1 (with red probe) to J3 pin 20 (with black probe) for 5VDC. If there is not 5VDC, then the door board is verified as being bad. If the voltages check good, then the water valve would need to be tested for voltage. The water dispenser valve can be tested for voltage at the door board at connection J4 pin 7 to J4 pin 16 when the water paddle is pressed. There should be 120VAC being measured if the board is operating properly, and if so, then the water filter, and water tank will need to be inspected. Read More...
Angela August 13, 2019 for Model Number GFE29HMEEES Could you please help we have this GE it is not freeze below 19 will not make ice in the under unit and is not much better in the lower unit. The refrigerate is only at 44 is it the Control Board #WR55X30806 we have had this for about 4years purchased from Sear store that was closing in our area. If you have any advise it would greatly appreciated. Thank you Angela
1 Answer Angela,It could be a board issue, but it could also be a defrost issue or even a sealed system issue. The refrigerator will need further diagnosis before we can determine the problem. You are welcome to call us at 1-877-477-7278 and one of our agents will help you through the process or you can call a technician to come out and check the refrigerator out. Read More...
Chuck P June 10, 2019 for Model Number CYE22TSHDSS 3 year old refrigerator is now shutting down occasionally - front panel lights are on, but no interior lights, water dispensing, or cooling. Unplugging the unit, and then plugging back in after a few minute pause will restart the unit and everything will operate normally, like a PC a reboot, but the issue reappears eventually. All coils and vents are clear of dust, and the unit is not overloaded, left open for long periods, or has any visible door seal issues. Suspect a main control board problem, any suggestions?
1 Answer Chuck,It sounds like the board again, you should check you outlet for proper voltage and polarity. Read More...
Eric May 19, 2019 WR55X30806 main board for a profile pfe29psdass. The inverter for the compressor is only getting 2.4VDC. Is the main board bad?
1 Answer Eric, the main control will send between 2-3 VDC to the inverter based on what compressor speed is needed. The main control would be working properly in this case. You may want to test the compressor WR87X10199 pins for resistance. The resistance between any two pins on the compressor should measure between 9 to 11 ohms, and all the pins will need to be tested to each other. If the compressor tests good, then the inverter WR87X29409 would be the issue. If the compressor does not test within the proper range, then the compressor is bad and a certified technician would be required to replace it. Read More...
Jim P. September 18, 2018 for Model Number PFE29PSDCSS My refrigerator isn’t cooling. I replaced the inverter and condenser fan and it cooled briefly (down to 42°F) before it stopped cooling again. I checked the contacts for the compressor and they were correct and it is running and warm. There is “air” blowing into the freezer compartment but it is just “cool”, not “cold”. Any suggestions?
1 Answer Hello Jim, You will need to remove the rear freezer wall to check the frost pattern. If there is an iceball where the Freon lines enter the evaporator compartment, there is a Freon loss. If the frost pattern behind halfway down the evaporator coils there is a sealed system restriction, and if the frost is only across the top of the coils, there is an air circulation issue. As a note, if the compressor is running and almost too hot to hold your hand to, there is a restriction in the sealed system that is overloading it. If you need assistance you can take a picture of the frost pattern and send it to us and most of the time we can tell what the issue is, or at least pretty close since the frost pattern is the most reliable diagnostic tool to an experienced technician. Simply give us a call at 1-877-477-7278 and we will assist as much as possible. Read More...
Robert S. July 14, 2018 for Model Number PYE23PSDESS There was a car accident that knocked a telephone pole down causing a power surge in my house. The refrigerator lights come on, the electronic display on the door works, etc. but no cooling. Do you think it is the control board needing replaced? (WR55X30452) Thank you
1 Answer Hello Robert, The main board WR55X46805C will normally be the cause of this issue under the circumstances described. Read More...
Don August 21, 2017 for Model Number GFE28hmhces Fridge has no power to anything, lights fan or compressor. I replaced the main control board and still have nothing. Yes i have power to fridge.
1 Answer Hello Don. The next step would be testing for power through the cord to the board and checking the wiring on the unit also. You need to trace and see where your losing power at. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Gabriela January 18, 2017 for Model Number PSW26LSRDSS All lights were on on the door panel and when I tried to get some water, the lights went off when I pushed in with my glass and no water dispensed. The lights came back on and I tried again, this time with the ice and the same thing happened. A few more tries and I gave up. I tried again later and water and ice were dispensed normally. Then stopped again and now the lights are off for good and the dispensing is off again... Ideas?