Eric for Model Number PFCF1RKZABB

Hi there, Last night my electricity went out. This morning when I got up, I saw that my GE Profile refrigerator was not working...at all. No lights, fans, or any sounds, whatsoever. I checked the fuse box...all was well. I checked all of the GCFI outlets and reset all of them. Nothing worked on the refrigerator. Other than the mother board being fried from a power surge, can you think of anything else I should check? Thanks so much for your help. I look forward to hearing from you! Eric

1 Answer

Eric,
Based on the information provided check as best as you can for no other shorts, then replace the shorted board and check the operation. WR55X11098C

Read More...

1 Answer

Walter, the main control would be tested for DC voltage at connection J9 pin 1 (with red probe of meter) to pin 2 (with black probe of meter). The voltage reading should be 12VDC. If there is 12VDC, then the red probe would need to be moved to pin 3 and it should read 0 or 5VDC indicating that the condenser fan motor WR60X23363 has failed.

Read More...

1 Answer

Brad, based on the information provided there would be a communication issue with the door board WR55X44126. The door board can be tested for a signal from the dispenser board when the dispenser paddle is pressed by testing from connection J3 pin 12 with red probe to J3 pin 20 with the black probe of a meter. When the paddle is pressed in, there should be a positive DC voltage reading. If there is, then the door board is not properly operating. The ice maker can also be tested from the board by testing from connection J5 pin 2 and then 1 (with red probe) to J3 pin 20 (with black probe) for 5VDC. If there is not 5VDC, then the door board is verified as being bad. If the voltages check good, then the water valve would need to be tested for voltage. The water dispenser valve can be tested for voltage at the door board at connection J4 pin 7 to J4 pin 16 when the water paddle is pressed. There should be 120VAC being measured if the board is operating properly, and if so, then the water filter, and water tank will need to be inspected.

Read More...

1 Answer

Angela,
It could be a board issue, but it could also be a defrost issue or even a sealed system issue. The refrigerator will need further diagnosis before we can determine the problem. You are welcome to call us at 1-877-477-7278 and one of our agents will help you through the process or you can call a technician to come out and check the refrigerator out.

Read More...
Chuck P for Model Number CYE22TSHDSS

3 year old refrigerator is now shutting down occasionally - front panel lights are on, but no interior lights, water dispensing, or cooling. Unplugging the unit, and then plugging back in after a few minute pause will restart the unit and everything will operate normally, like a PC a reboot, but the issue reappears eventually. All coils and vents are clear of dust, and the unit is not overloaded, left open for long periods, or has any visible door seal issues. Suspect a main control board problem, any suggestions?

1 Answer

Chuck,
It sounds like the board again, you should check you outlet for proper voltage and polarity.

Read More...

1 Answer

Eric, the main control will send between 2-3 VDC to the inverter based on what compressor speed is needed. The main control would be working properly in this case. You may want to test the compressor WR87X10199 pins for resistance. The resistance between any two pins on the compressor should measure between 9 to 11 ohms, and all the pins will need to be tested to each other. If the compressor tests good, then the inverter WR87X29409 would be the issue. If the compressor does not test within the proper range, then the compressor is bad and a certified technician would be required to replace it.

Read More...

1 Answer

Hello Jim,
You will need to remove the rear freezer wall to check the frost pattern. If there is an iceball where the Freon lines enter the evaporator compartment, there is a Freon loss. If the frost pattern behind halfway down the evaporator coils there is a sealed system restriction, and if the frost is only across the top of the coils, there is an air circulation issue. As a note, if the compressor is running and almost too hot to hold your hand to, there is a restriction in the sealed system that is overloading it. If you need assistance you can take a picture of the frost pattern and send it to us and most of the time we can tell what the issue is, or at least pretty close since the frost pattern is the most reliable diagnostic tool to an experienced technician. Simply give us a call at 1-877-477-7278 and we will assist as much as possible.

Read More...

1 Answer

Gabriela,

You will want to check the wire harness connection at the door hinge to make sure that there are not broken or damaged wires. This would be the most probable cause for this issue.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google