1 Answer

Cathy, based on the information provided, the most likely cause of failure would be the water valve 5221JB2010G located behind an access panel of the left door at the bottom just behind the door bin.

Read More...

1 Answer

Mike, as the arm is able to fall in this manner, replacing the ice maker for your model would be necessary.

Read More...

1 Answer

JOANNE,
Based on the information provided the ice maker for your model is our part number AEQ36756901
Here is a link to the part and price... https://www.appliancepartspros.com/lg-ice-maker-assembly-aeq36756901-ap4442284.html

Read More...

1 Answer

Marie,
The first thing to check is that the temperature at the ice maker is below 8°F. If the temp is not below 8°F then the ice maker will not start a cycle.

Read More...

1 Answer

Mike, it would be recommended that the freezer temperature is verified using a thermometer. If the freezer is not reaching a temperature of 0°F, it can stop the ice maker from properly making ice. If it is reaching proper temperature, the ice maker fan ABA72913403 in the freezer would need to be checked for proper operation along with inspecting the vents going to the ice maker section for any blocked openings. Inspecting the door gasket ADX72909701 on the ice maker door for an air leak would be necessary as well.

Read More...

1 Answer

BAHS, as the ice maker and the auger motor will not operate, the door switch would need to be tested for continuity when it is activated. If it has continuity, the main control EBR61439205 would be the most likely cause of failure based on the information provided.

Read More...

1 Answer

Mike,

The most likely scenario for this issue is that the water valve is seeping. This would allow a trickle of water to bypass the valve and freeze in the ice tube. If you have the energy saver feature on then this can cause the heater to shut off for the fill tube and it will allow freezing.

Read More...

1 Answer

Ernest, unfortunately, the model provided appears to be a partial number. If the full model could be verified and provided in a new question, this may allow the most accurate information to be presented. Generally speaking, if the line is not frozen, the ice maker would need to be placed into a harvest mode and the water valve tested for voltage to identify if the valve is receiving the necessary power to operate. If it does and water does not enter the ice maker, the valve has failed.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google