The Nozzle is an OEM part for LG ranges. It is a small component located inside the burner box that emits gas to create flame. During operation, the nozzle precisely meters fuel flow to each burner to achieve balanced and consistent heating. 

Symptoms of a faulty nozzle include: 

  • Burners that light unevenly or emit an irregular flame pattern
  • Inability to adjust burner flames or in some cases, lack of ignition
  • Possible safety hazard from gas emissions not mixing or igniting properly

Causes can stem from mineral buildup clogging the narrow opening over time. Damage, such as nicks or corrosion, may also disrupt critical gas flow.

This OEM LG part is also compatible with some Kenmore ranges featuring LG gas cooktop systems. Replacing a worn nozzle restores optimal and safe burner performance.

More
$19.45
Compare At:
$23.34
You Save:
$3.89

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Lg Nozzle (Part Number: OEM15771099)

1 Answer

Victor, the following parts will convert your cooktop back to nat gas. {AP6011379} - 71002722 - HOLDER W/ORIFICE (10K) Note: HOLDER, ORIFICE (NAT-LT/REAR) {AP4088998} - 71002721 - HOLDER W/ORIFICE (9.1K) Note: HOLDER, ORIFICE (NAT-RT/REAR) {AP6011378} - 71002720 - HOLDER W/ORIFICE (6.5K) Note: HOLDER, ORIFICE (NAT-LT/FRT) {AP4089018} - 71002723 - HOLDER W/ORIFICE (12K) Note: HOLDER, ORIFICE (NAT-RT/FRT)

Read More...

1 Answer

Lmm This nozzle would be a natural gas orifice and to get the LP orifice you would need to get the conversion kit.

Read More...

1 Answer

Tom, the parts you will need to convert it to natural gas are as follows: front left orifice [MFV61841503], rear left orifice [MFV61841504], center orifice [MFV61841504], right rear orifice [MFV61841507], right front orifice [MFV61841508]. You will also need to adjust your regulator, as well as the bake and broil burner caps, for natural gas. The adjustments can be found in the user manual by reversing the lp conversion.

Read More...

1 Answer

Bc, Your front left orifice should be stamped with a C, back left is stamped G, back right is stamped D and the last one goes in the front right. I'm sending you a manual for conversion to lp so just reverse the instructions to go back to lp.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store