Mike March 23, 2018 for Model Number WF42H5000AW/A2-0000 This model comes with a switch that has no adjustment screw to alter the water level (DC96-01703G). Could this part DC96-01703B or DC96-01703C be used in place of DC96-01703G ?
1 Answer Mike, Unfortunately you would want to use the part that the manufacturer recommends for your unit. These are not designed to be adjusted for water level and are preset. Read More...
Rav November 22, 2016 for Model Number WA422PRHDWR/AA-0002 Every 3 months I am getting 1E code, so I replace Water Pressure Switch. This last time I replaced and machine still wouldn't start and yes the machine was unplugged when I worked on it, so it could rest. Is there something else I should replace, so I don't have this reoccurring problem. This is 3rd time I had to replace this part. This machine is 42 months old and I feel its a pc of junk.
1 Answer Rav, With this issue you will want to check the pressure hose that comes off the water level sensor to make sure that it is not kinked or clogged. If this checks ok then the issue will be with the main PCB that is faulty. Read More...
Singh October 01, 2016 for Model Number WA45H7200AW/A2-0000 Steps to test Water level pressure switch using multi meter.
1 Answer Hello Singh. You will access the switch and unplug the wires going to it. The 2 outside pins should read around 21ohms and the center to outside should read infinity. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Trent July 08, 2016 for Model Number WA400PJHDWR/AA Followup question to my previous question on continuity readings. I got out my actual multimeter instead of my test light, here are the readings I get: 23.2 ohms between the two outside pins open/infinity between the center pin and either outside pin. Everything I've been taught about contacts is they need to be less than an ohm or they are bad, is 23 ohms too much for this part? Also, I tried applying pressure via blowing on the tube to change the switch's state and none of my reading changed, is this normal?
1 Answer Hello Trent. Readings are a little off but if it didn't change, then the switch is bad. Thanks. Read More...
Trent July 06, 2016 for Model Number WA400PJHDWR/AA What should be the continuity reading on this switch? I get open\infinity between the middle pin and either of the outer pins. I get 0 ohms between the two outside, is this right?
Romulus A November 06, 2015 for Model Number WA456DRHDSU/AA-0001 I replaced the drain pump on my two year old Samsung WA 456 washer. The new drain pump is running non stop, draining all the water that goes in the washer. It is so frustrating, please help! Regards, Romulus
1 Answer Romulus, If the drain pump is constantly running then the issue will be either a pressure switch that is not resetting or a faulty control board on the unit. Check the pressure hose to make sure that it is not clogged. Read More...