Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Refrigerator Temperature Control Thermostat by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM18029805
Manufacturer Part Number: WP61001673

Fix a refrigerator that runs constantly or won't cool properly. This temperature control regulates cooling cycles. Moderate DIY repair for most models.

More
$120.56

Out Of Stock

Usually ships within 4 - 14 days

Add to Cart

Questions & Answers

For Whirlpool Refrigerator Temperature Control Thermostat (Part Number: OEM18029805)

1 Answer

Hello Sharad,
unfortunately, we do not have a video for that part replacement at this time. However the cap line does extend through the center wall of the ref into the freezer, you may want to disassemble the top of the ref and frez interior to be sure the new control's cap line is routed correctly.

Read More...
Leopoldo F for Model Number RSD2400 EAE, DAE & AAW

Few days ago you giveme a clear and simple explanation to connect the thermostat of my MAYTAG (¿WHIRLPOOL?) RSD 2400. The thermostat is damaged and a need to buy a new one but when i go to the chek box to obtain the proper thermostat for my frigo, in adittion of the RSD2400 code, this model have three terminals variants, EAE, DAE & AAW. I don't find in the body of my refrigerator no one of this three variants. My question is: Will be the same thermostat that appear as the proper one for any one of the three variants? Again, I'll be gratefully with yours helpful indications.

1 Answer

Leopoldo,

The part number for the defrost thermostat for this unit will be WP52085-29 and will be the same for all of the series of this model.

Read More...

1 Answer

Leopoldo,

Based on the wiring diagram of the unit there would be all the red wires going into 1 terminal and the blue to the other terminal with the ground on a separate terminal. This part only has 3 terminals to it.

Read More...
Jerome for Model Number Maytag RSD2200DAM

My Maytag Refir is about 10 years or so old. Mod RSD2200DAM , S/n 10605336KK . The defroster didn't work ( heater was melted in 2) so replaced all parts, now it leaves ice on freezer floor , hav'ta check drain. Cleaned condenser coils The original cold control would run refriger down to 20 deg F with dial on .5 , Yes ! Point 5, I.E. less than 1 ! damper open or closed ! Freezer at about 0 deg .It runs a lot ! Bought your cold control ,its different than pic &way different then old unit, installed it . At .5 on dial it keeps refrig at 32 deg F ,freezer at 10 deg. Unit still runs a lot ! Turned dial dwn to .3,unit turned on at 52 deg,freezer at 25 deg. Is it possible to get more adjustability W/ Out having to leave frig door open ?

1 Answer

Jerome, it sounds like you may have gotten the incorrect cold control, you should have part number WP61001673, as far as the ice on the freezer floor, make sure the drain is clear, you should be able to pour warm water through the drain without it backing up into the floor of the freezer.

Read More...

1 Answer

Mike,

The temperature control tube would not go into the freezer compartment but should be located near where the freezer control damper is on the unit on the housing for the damper.

Read More...

1 Answer

Tom,

Either there is a bad connection to the defrost timer or the defrost timer is faulty. The thermostat does not control the defrost timer advancing.

Read More...

1 Answer

Hello Al. Make sure condenser coils are clean and the condenser fan motor is running. If that is good, replace the temp control WP61001673 on the unit.

Read More...
Lee for Model Number Magic Chef refrigerator/Freezer model 415S

We have had this appliance for several years although it has not been used on a constant basis. My daughter took it to college and everything she puts in the refrigerator is freezing. She has turned it off and it defrosted but when she turned it back on it did the same thing again. She has also tried turning it down but nothing really seems to help. It is the perfect size refrigerator, especially for her dorm room, and it has a freezer which she loves. It may not be worth the cost of repairing. Do you think it needs the thermostat replaced or a temperature control part? Any help you can give us would be appreciated. Thanks in advance. Lee

1 Answer

Lee,

This issue does sound like it would be caused by a bad thermostat. The part number for the thermostat that you would need is 312180100012.

Read More...

1 Answer

Karen, The cold control is located behind the light shield, in the metal box mounted to the wall " 1. disconnect the unit from poer source. 2. remove the light shield and remove the mounting screwsfrom the control housing. Disconnect the ground wire from the wiring cover. 3. Disconnect the electrical leads from the control terminals. 4. Straighten the metal tabs that retainthe feeler tube loop. Unsnap the control from the housingand rmove it with a twisting motion. 5. Install the new control in reverse order of removel procedure. Reinstall ground wire."

Read More...

1 Answer

Hello Bob. Did you melt all the ice off the coils and have you checked to make sure the heater is working after you installed the new heater. If not, or if the heater is not working, it may be the defrost thermostat or the defrost timer. Remember after the part is installed, you will need to melt any ice off the coils to have the unit cool properly.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google