Skip to Content
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • 15 million satisfied customers 15 million satisfied customers
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store

Customer Questions and Answers for Dryer Gas Burner Tube With Adjustable Air Shutter by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM18031800
Manufacturer Part Number: WP693140

If your dryer won't heat or flame won't stay lit, a corroded burner tube may be the cause. This assembly includes an adjustable air shutter for proper combustion.

More
$87.40
Compare At:
$104.01
You Save:
$16.61

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Dryer Gas Burner Tube With Adjustable Air Shutter (Part Number: OEM18031800)

1 Answer

Hello Shannon, You would want to check your main coil. Let the unit cycle 4 or 5 times and then check resistance of the 2 pin main coil. You should read 1000 ohms. If you do not have 1000 ohms then you need to replace main coil 279834. If you do have the 1000 ohms then you would need to replace the safety valve WP8318277.

Read More...

1 Answer

Hello Jeff. If the spark came from the timer, and not a bad wire, you will need to order and replace the timer in the unit.

Read More...
Green for Model Number WGD9600TW0 Whirlpool Duet Gas Dryer

The dryer will not maintain heat. I replaced the thermal fuse and the 2-prong gas valve coil because my husband already ordered them and he thought that would fix the problem. After that didn’t work, I started from scratch and watched all of the videos. The burner igniter glows bright orange for a few seconds, the blue gas flame can then be seen blowing through the burner tube, then the flame switch clicks off. The blue gas flames continue for about a minute and the dryer appears to function normally with sufficient heat inside the drum. Then the flame switches off for a minute, and the cycle starts over (starting with the burner igniter glowing). After the cycle repeats a few more times, the dryer continues to run without any more heat. I noticed the top prong of the 2-forked bracket (that holds the igniter to the burner tube) is getting scorched when the blue flame is burning. It looks like a little bit of the flame is escaping to the left more than it should. (I wondered if I created a draft because I had the bottom panel off in order to observe everything). What is my next step? It seems as if most of the problems people listed involved not getting the burner to come on, or turn off, or not getting any gas or electricity. I can’t find a posting that already has those things covered. Thank you for reading my post.

1 Answer

Hi Green. It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly. Thank You.

Read More...

1 Answer

Hello Kenya. It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly. Hope this helps.

Read More...

1 Answer

Hello James! The model LGQ8858JQ8 seems to be invalid, I have located model LGQ8858JQ3. Yes, the gas conversion kit is available for purchase, part number 49572A. Thanks!

Read More...

1 Answer

Tony, you can repair it yourself, with a little time, patience, and basic hand tools. You most likely have a weak set of gas valve coils 279894 , If I understood your post, the glow bar igniter glows, then it shuts off, but there is no flame from the burner, correct ? Thanks and Good Luck.

Read More...

1 Answer

Hello Robert. You will need to test the coils after running the dryer for a few minutes. They can give false readings before operation. It sounds like the coils are bad. Hope this helps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store