Robert G July 23, 2023 for Model Number WRT108FZDB02 Freezer temperature is 40 degree and the lower compartment is about 60 degree. What could be the problem and what is the fix?
1 Answer Robert G,You will need to know what all is running, compressor, fans...etc. If the compressor and the fans are running you will need to know if the evaporator is frosted up like a defrost issue or if it is just partially frosted or not frosted at all. This could be a defrost issue or a sealed system issue. Read More...
Max April 15, 2022 for Model Number WRT318FZDB00 Since about 6 months ago I've had to remove ice & frost buildup in the freezer. Sometimes there is even water that drips in the refrigerator. Every time, I have disassembled the back panel of the freezer and removed all ice, poured hot water in the drain tube, but 3-4 weeks later is happens again. I have found a few helpful posts with instructions on how to measure resistance on different parts (defrost heater, freezer thermistor, white+brown wire in the control box) but all of the readings seems to be normal. Anything else I should try before replacing the control board? Thanks!
1 Answer Max, If the evaporator coils are icing up all over then it would be the control board that is faulty. If it is just the drain that is freezing up then use part number 819043 in the drain to keep it from freezing up. Read More...
Renal April 04, 2022 for Model Number WRT519SZDM01 I think I gave too much information the first time. The drain is not blocked. The reason everything was that frozen is because the entire coils were frozen solid. The compressor ran overtime to cool the fridge (where the sensor is) but was unable to because of the blocked ports. The bottom collection tray and tube are frost free, but the coils become a frozen block. My freezer keeps frosting up, I have to remove back panel and defrost the coils inside the freezer every few weeks. I will check the resistance of the defroster element, but is the electronic control board what controls the defroster or is there another timer inside the unit (like the older models that has a physical timer) to decide when to defrost? I have a few parts that could be bad- Control board (defroster timer), low freon, or defroster element. I wondered if the thermostat could be bad, but I do not remember hearing the defroster kick in and it is clearly cooling.
1 Answer Renal, usually, for the vents going to the refrigerator to clog up, moisture would have been accumulating either from clear ice at the pan under the evaporator (a slow drain can cause similar failures) or from excessive moisture entering into the refrigerator section. When this occurs, the evaporator will become congested with frost build-up. In regards to the defrost cycle, it is controlled by the main control WPW10643378. The defrost heater WPW10316428 and the bi-metal in the harness W11502499 can be tested from the main control when the power cord is unplugged. With the 6 wire connector unplugged, the defrost circuit can be tested from the brown wire to the white wire with a meter. There should be a resistance reading between 30 to 42 Ohms if the bi-metal and heater are good. Read More...
Renal April 04, 2022 for Model Number WRT519SZDM01 My freezer keeps frosting up, I have to remove back panel and defrost the coils inside the freezer every few weeks. At one point the freezer was -20F and the fridge was 50F. I found out that the holes going from the freezer to the fridge were frozen shut. I will check the resistance of the defroster element, but is the electronic control board what controls the defroster or is there another timer inside the unit (like the older models that has a physical timer) to decide when to defrost?
1 Answer Renal, The control board would not be the issue. This will be an issue with the drain under the evaporator in the freezer getting clogged and freezing. You will want to clean the drain and flush it. Read More...
David February 05, 2022 for Model Number WRT318FZDM02 Refigerator is cold the freezer is not cold enough thermostat says 20 changed the capacitor, overload relay and the two thermistors i only have frost build up on the upper right side near the thermistor on the evaporator
1 Answer David, Thanks for the question!!! Unfortunately, you have a sealed system issue and will need an EPA-certified technician. Read More...
Jeff January 04, 2022 for Model Number WRT318FZDB05 My refrigerator is freezing everything in the fridge section, freezer seems to be working fine. Could you help me out with possible solutions? Thanks!
1 Answer Jeff, the thermistor W11438736 would need to be tested for resistance and it should measure 7.6k Ohms at 37°F, and 8.8k Ohms at 32°F. If it tests within a 10% margin of the resistance checks, the failure would be in the main control W11436574. Read More...
Luis October 14, 2021 for Model Number WRT519SZDM01 I replaced the control on my fridge and now it is running but the new one only has 3 of the led lights lighting up and the previous one had 4. I'm sure I got the right part, is there something I need to do to reprogram the board?
1 Answer Luis, the control WPW10643378 would not have a reprogramming capability as the manufacturer has it preprogrammed for plug and play capability. It would be recommended that the control is double-checked to ensure it has lined up properly in the housing and that there is not debris between the LED of the control and the viewport of the housing. If these all check good, it is likely that the LED of the control is faulty. Read More...
Scott October 05, 2021 for Model Number WRT148FZDM00 Hi My model WRT148FZDM00 is just over two years old, and in the last few weeks, we are having fresh produce, like lettuce freezing. I did try to test the thermistor, if I did it right I received 2.7ohms at room temperature. Temperature at times reaches the required temp. but through out the day fluctuates down to as much as 28F, but can stay for a while at 36F to 42F.
1 Answer Hello Scott, due to the erratic temperatures since the thermistor ohms correctly then the control would be at fault it is part WPW10643378. Read More...
Anko March 07, 2021 whirlpool refrigerator( 3 years old) mod.WRT318FZDM02 Refrigerator to cold and freezer not cooling enough Replaced termistor and capacitor and still doing the same
1 Answer Anko,Try adjusting the freezer setting to coldest, that should block off some air going to the refrigerator section and keep it in the freezer area. The only other possibility is the control is not reading the thermistor correctly and would need to be replaced. WPW10643378 Read More...
Mud November 02, 2020 for Model Number wrt318fzdm02 Fridge was freezing everything in the FF section so I replaced the thermistor. Then the freezer section stopped freezing. Cleaned condensor coils and verified fan is working. Evap fan is good, motor was replaced. Still not freezing. Significant ice build up in the top right corner above the fins inside the freezer. Is there a way to test the control board to verify if this is a bad control board or a sealed system issue?