J. B. May 14, 2020 for Model Number WED9400SW0 My dryer is not functioning properly. I've tested the thermal fuse. When I hit the power button it will not come on. But, if I hit the start or other buttons on the user-interface the power will come on. Then, if I keep hitting buttons on the user interface the power will go back off. The dryer has worked well for many years but in the last month, it started acting funny. We'd have to turn it off and on a few times and play with various settings and then it would work. eventually, the behavior of the machine is that we can't get it to work at all. I suspect that the problem is with the user interface but curious if there is some way to confirm that prior to ordering a replacement kit.
1 Answer Hello J., As per the tech sheet ACTIVATING THE SERVICE DIAGNOSTIC TEST MODE1. Be sure the dryer is in standby mode (plugged in with all indicators off, or with only the Done indicator on).2. Select any one button (except Pause/Cancel) and follow the steps below, using the same button (remember the button):a. Press/hold 2 secondsb. Release for 2 secondsc. Press/hold 2 secondsd. Release for 2 secondse. Press/hold 2 seconds3. If this test mode has been entered successfully, all indicators on the console are illuminated for 5 seconds with 8:88 showing in the Estimated Time Remaining three-digit display. If there are no saved fault codes or active fault codes, all indicators on the console will momentarily turn off, then stay on with 8:88 displayed. Continue with Diagnostics.4. If entry into diagnostic mode is unsuccessful, choose a different button (except Pause/Cancel) and repeat step 2. This is all explained in the tech sheet located in the plastic bag affixed to the inside of the front of the cabinet. You should also be sure to check the connections to the user interface, the door switch, and the thermistor. Read More...
Goose September 04, 2018 for Model Number WGD9400SW1 What do I need to replace for the Start Button Sticking or can I lube it? Thanks
1 Answer Hello, unfortunately it sounds like the actuator or the electrical portion of your user interface W10294629 is starting to fail. The only way to replace that would be by replacing the interface, thanks! Read More...
Eric September 14, 2016 for Model Number WED9400SW0 My user interface has suddenly become non-responsive with no lights. The dryer light functions normally when the door is open. I ordered a replacement user interface from you which arrived today, but it is still non-responsive. I tested the two wires which go to the UI and they both show power of approx 10V. Is this the correct amount of voltage going to the UI? Could the replacement UI be bad? Any suggestions would be greatly appreciated.
1 Answer Eric, if the P3 connector pins 1 and 2 has 5 to 10 volts at the U/I connector, then the display should illuminate. Recheck and make sure the U/I is properly installed and snapped and locked into place properly, and check the other wire harness to make sure it is seated and locked in place, before you reorder a U/I. Read More...
Gordon August 02, 2016 for Model Number WGD9400STO Getting the F01 error code. Do I need the User Interface Control Board?
1 Answer Hello Gordon. F:01 flashes when there is a primary controlfailure.¦ Replace the machine control electronics. Read More...
Troy November 12, 2015 for Model Number WGD9400SB0 The user interface won't power on but the drum light turned on when I open the door. Is this means I need to replace the User Interface Control Board?
1 Answer Hello Troy. You need to test for power to the interface and replace it if there is power there. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
1 Answer Hello Randy, This will most likely be a thermistor. The outlet thermistor WP8577274 should read about 10k ohms and is located on the blower shroud. If this does not correct the issue, the control WPW10110641 has most likely experienced an issue. Read More...
1 Answer Hello Robert, The following is quoted from the service manual on a similar model since we do not have access to the sears service manuals. REMOVING THE CONSOLE & THE TOUCHPAD SUBASSEMBLYNOTE: Sharp edges may be present.1. Turn off the gas to the dryer and disconnect the electrical power.2. Pull the dryer away from the wall and remove the top cover.3. Remove the three hex-head screws from the rear flange of the dryer’s top cover. NOTE: The top cover screws have nylon flat washers on them. Be sure to use these screws when you reinstall the top cover. 4. Lift the rear of the top cover and slide it back so the tabs clear the catches on the bracket, and remove the cover from the unit. NOTE: Make sure that the tabs slide under the bracket catches when you reinstall the top cover.5. Remove the three screws from the machine control electronics board bracket and pull the bracket away from the side of the dryer so you can access the connectors. 6. Disconnect the ends of the two ribbon cables from the machine control electronics board connectors P3 and P4. 7. Remove the two screws from the console bracket.8. Open the door and pull out on the bottom of the console to release the locking tabs from the door panel. 9. Lift the console straight up until the brackets are free of the left and right side panel flanges and remove the console. 10. Place the console assembly on a padded work surface with the bracket side facing up.11. Remove the four hex-head screws from the console bracket and remove the bracket.12. Remove the selector knob.13. Remove the touchpad subassembly from the console by unsnapping the six catches. Use your thumb or a screwdriver. From this point, aside from the small variances (since this unit was built exclusively for Kenmore), the two-part control should come out simply with a bit of difficulty. Read More...