1 Answer

Bob,

You will want to check the high limit thermostat, the thermal fuse to make sure that they are ok. Check for a broken or inoperative igniter, open flame sensor and check the coils on the gas valve to make sure that they are good. If any of this checks bad then replace it. The control or logic board would be the last thing to suspect for not heating.

Read More...

1 Answer

Hello Kale. If everything checks out on the unit, and the unit shuts off, either it is a loose connection or the board is bad and needs to be replaced.

Read More...

1 Answer

Abbs, the ribbon cable that installs on the logic board WP31001562 is only available with the control assembly, part number 31001658. Yes, if the ribbon cable is shorting out it will not accept commands/send signal to the board. Thanks.

Read More...

1 Answer

Keith, You're on track, it's most likely a faulty control board WP31001562 like you think. But if your dryer is an Electric model, make sure and reset both breakers and you have 240 volts to the dryer. We're sending you some information that should help you diagnose and repair your dryer properly. Thanks

Read More...

1 Answer

Hello Roy. If the unit is acting like a button is stuck and not taking commands properly, replace the control panel 31001660. If the unit takes commands, but does not operate properly, replace the control board WP31001562. Hope this helps.

Read More...
Raymond for Model Number Maytag Neptune Drying center

I am experiencing very erratic behavior. The upper cabinet can turn on by itself (or turn on when the controls for the bottom cabinet are pressed). Sometimes buttons (such as 'time dry') do not respond. The unit frequently continually cycles through the dryness settings ('damp dry' through 'very dry'). Recently, the unit turns itself off as soon as the 'Start/Pause' button is depressed on the lower cabinet. This makes the unit completely unusable. Is this a problem with the keypad or the logic board.

1 Answer

Hello Raymond! Try replacing the control panel/touch panel. This should correct the issue you are having. We will need the appliance model and serial number to help verify the correct part number needed for your unit. Thanks!

Read More...

1 Answer

Hello Jim. Yes, it is either the logic board WP31001562 or a bad control panel 31001658. You will need to check and see if the start button on the control panel is sticking, and causing the unit to turn on. If so, you will need to replace the control panel. Hope this helps.

Read More...

1 Answer

Hi Bullavard. The thermister is mounted on top of the blower housing. This part # is WP31001590. The thermistor tells the board what temperature peramiters are there. If it is shorted out of calibrations then it will make the board think it has already dryed the cycle. Thank you.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google