Alexander July 08, 2023 for Model Number KSRB25Q Looking for a replacement of the start relay OEM part 1101014
Frank A. August 04, 2020 On replacement kit ap3120015, do the wires connect to the 3 pins on the compressor?
1 Answer Hello Frank, As per the instruction sheet, there are 4 ways to use this kit depending on the application:Procedure 1Compressor with no capacitorA. Unplug refrigerator or disconnect power.B. Remove relay cover, relay, and overload.C. Assemble plastic straps. Two should be long enough to go around the compressor.D. Assemble the strap and PTC.E. Attach PTC to the compressor with strap, leaving PTC loose against compressor and red and blue leads toward terminals.F. Connect leads with terminals from PTC to compressor terminals. Red wire to M and the blue wire to S. G. Connect white wire terminals from the junction box to compressor terminal C. If the white wire does not have pin terminal, cut off terminal, strip insulation 3/8" from the end and attach pin terminal supplied in the kit.H.Cut terminal from the end of the red (or black) wire coming from the junction box, strip 3Ú8" insulation and splice to red wire marked L on PTC with wire connector supplied in the kit.I. Read the note on page 1 before applying sealant. Apply sealant liberally to PTC relay and pull the strap tight. Use pliers to tighten the strap.J. Place wire connector under relay cover and attach the cover to the compressor.Procedure 2Compressor with a start capacitor (Identified as rated more than 50 MFD)A. Perform (A through E) as in Procedure 1.F. Cut blue wire between PTC and compressor terminal. (Wire should be cut so that connections can be placed under relay cover.)G. Cut terminals off start capacitor leads.H.Strip insulation I. Splice each end of blue wire to a capacitor lead using wire connectors furnished.J. See paragraph H in Procedure 1.K.Connect white wire with terminals from the junction box to compressor terminal C. If the white wire does not have pin terminal, cut off terminal, strip insulation 3/8" from the end and attach pin terminal supplied in the kit.L. Apply sealant. See paragraph I in Procedure 1.Procedure 3Compressor with a run capacitor (Identified as rated less than 20 MFD)A. Perform (A through E) as in Procedure 1.F. Cut both red and blue wires between PTC and compressor terminals. Both wires should be cut so they can be placed under the relay cover.G. Strip insulation 3/8" from all four (4) wires.H. Splice both ends of blue wire to one (1) capacitor lead and both ends of red wire to other capacitor lead with the wire connectors furnished.I. See paragraph H in Procedure 1.J. Connect the white wire with terminals from the junction box to compressor terminals C. If the white wire does not have pin terminal, cut off terminal, strip insulation 3/8" from the ens and attach pin terminal supplied in the kit.K. Apply sealant. See paragraph I in Procedure 1.Procedure 4Compressor with run and start capacitorsA. Perform (A through E) in Procedure 1.F. Cut both red and blue wires between PTC and compressor terminal (wires should be cut so that connections can be placed under relay cover).G. Strip insulation 3/8" from all four (4) wires.H. Splice both ends of red and blue wires of the run capacitor and start capacitor leads with wire connectors. I. Cut terminal from the end of the red (or black) wire coming from the junction box, strip 3/8" insulation, and splice to the red wire from PTC with wire connector supplied in the kit.J. Connect white wire with terminals from the junction box to compressor terminal C. If the white wire does not have pin terminal, cut off terminal, strip insulation 3/8" from the end and attach pin terminal supplied in the kit.K. Apply sealant. See paragraph I in Procedure 1.So, in short, all three wires cannot connect to the compressor but where they connect depends on the application. Read More...
Bennie August 08, 2019 for Model Number 198619420 I have an old chest freezer . I moved it from my sister's and it stayed unplugged for approximately 2weeks. When I plug it up it will hum but then clicks off. Can you advise me what to do.
1 Answer Bennie, based on the information provided, the most likely cause would be that the start relay 4318083 has failed and is not allowing the run windings to operate separately from the start windings when necessary. There is a small chance that the windings of the compressor may be bad, but most commonly the relay fails. Read More...
Fred Peter May 21, 2017 for Model Number Coldspot Model 106724231 15.9 cubic foot freezer I have a 43 year old Coldspot Model 106724231 15.9 cubic foot freezer and it still works! I can't determine the horsepower rating of the compressor. I think the compressor overload relay is going out because sometimes the relay "clicks" periodically for 5-15 minutes before the compressor starts. There are separate overload and start components on this unit. Your compatability check indicates AP3120015 will replace both components. Is AP3120015 an integrated solid state unit? Will AP3120015 plug into the three pins on my compressor? If not, do the instructions indicate how to wire AP3120015 to my compressor pins? Thank you. Fred Peter
1 Answer Fred, The overload relay kit is integrated solid state and would just plug onto the compressor using the wires attached. There will be instructions that come with the kit. Read More...
Gene November 21, 2016 for Model Number Whirlpool EET201MKYR1 The refrigerator is not cooling. When powered on the fan runs fine and then the compressor motor turns on but a few seconds later the overload sparks and the motor turns off. The overload part is labeled with 851505. What part is compatible and do you think that is the failing part?
1 Answer Hello Gene. Here is a link to our Repair Forum, this is a free service to our customers. Use this link to access the repair for your question. http://forum.appliancepartspros.com/refrigerator-freezer-repair/193358-freezer-fridge-not-cooling.html Read More...
Darrin June 01, 2015 for Model Number 106723520 My Sears stand up freezer has stopped working. I turned off the thermostat.When I turn it back on I can hear the compressor start up but then shuts off in less than a full second. Is this the overload relay or something else?
1 Answer Hello Darrin. Here is a link to our Repair Forum, this is a free service to our customers. Use this link to access the repair for your question. http://forum.appliancepartspros.com/refrigerator-freezer-repair/193358-freezer-fridge-not-cooling.html Read More...
David January 13, 2015 for Model Number 1988183380 I'm having a problem with the freezer not starting. I can hear a humming noise from the relay on the compressor, so I orderd the start relay and the overload. The start relay looked the same but the overload relay kit is different. I have to wire it in and I really don't understand the directions because it looks like they are having you wire it to the compressor and it eliminates the start relay.
1 Answer Hello David, It sounds like you have the instruction sheet for the part. Follow these instructions and the compressor should start up with no problem. I have installed these and you just have to do as the sheet instructs. It will work. Read More...
Ricky September 21, 2014 for Model Number kenmore 198717640 Kenmore freezer model # 19871764. Would overload relay kit 819160 replace 592399?
1 Answer Hello Ricky! Yes, the relay/overload part number 819160 replaces the discontinued part number 592399. Thanks. Read More...
Brad May 14, 2014 I have an old Sears upright freezer. The overload, part 483012, heated up, was glowing and melting in one spot, and smokes. Smoking isn't good. When it is first plugged in it seems to be running. Could there be another problem that caused this or is it likely that changing this overload will solve the problem? Thank you, Brad
1 Answer Hello Brad. You need to replace the overload and see if the issue is resolved. If not, then the compressor will need to be replaced. Read More...
Michael December 27, 2013 for Model Number 1067627210 My Sears Coldspot refrigerator appears to need a new Overload/Relay Switch (has stopped cooling and "Clicks" every 2/3 minutes). Your web site offers an Overload/Relay Kit (AP3120015) made by Whirlpool which it says "replaces old style" switch. However, when I checked it with your compatibility function I received the message that the part is "Not Compatible" with my particular model and offers no other alternative. So... Is it compatible or not - and if not what other options do you suggest?
1 Answer Hello Michael. The original is no longer available. You need to order part number 819160. Thanks. Read More...