For Whirlpool Sensor, Tub (Part Number: OEM12112149)

1 Answer

Hello Julie,
unfortunately, the manufacturer only has the sensor bars as part of the sensor assembly which they have discontinued.

Read More...

1 Answer

Don, as the part is no longer available, with the wiring in the condition it is in that would leave an exposed voltage condition. We would not be able to recommend an alternative "fix" for this repair.

Read More...

1 Answer

Robert,
'm sorry but this part has been discontinued by the manufacturer and no satisfactory substitutions have been provided.

Read More...
Manny for Model Number LDG9804AAM

Been dealing with damp clothing. Replaced the multi temp sensor and hi limit thermostat. But it seams that now it gets hot to a point but on the last of the drying cycle clothes are damp. Using the electronic sensor. So my question, could this be caused by the moisture sensor and if so, how do you check this? I feel it is not a exhausting issue but is there a way to check this the exhausting duct, meaning is there a limit as to what is a partical obstruction or maybe a design flaw. Exhaust goes on a rectangular wall duct, then eventually on a round flex to a stove pipe to the roof. A long way but it gets there. Comment on duct and moisture sensor. Please.

1 Answer

Hello Manny. You have a venting issue. Run the dryer without the vent hooked up and see if it I dries properly. If so, then the issue is the dryer vent.

Read More...
Am52user for Model Number LDG4000AAW

I have a Maytag LDG4000AAW gas dryer that stops before the auto dry cycle has completed. This happens in both Auto Dry Permanent Press and Auto Dry Regular Fabric. It always cuts off in the final phase before the timer has advanced fully to the Stop position. The burner is cycling on/off properly and the air exhaust is venting well. Could the moisture sensor be causing this problem? Also, the Air Fluff unction does not work at all. It doesn't matter where you place the control knob in Air Fluff, when you press the start button it just emits a buzz. Any help you can provide on these problems would be greatly appreciated.

1 Answer

Am52user,

Yes the sensor bar could cause the unit to shut off prematurely and you would want to try to clean the sensor bars with some rubbing alcohol and see if this does not correct the issue. If the issue continues would recommend replacing the sensor 304997.

Read More...

1 Answer

Ronald,

If you open the door of the dryer and look inside on the front where the ducting is located the sensor will be right there.

Read More...

1 Answer

Hello Steve,
You will need to verify a full 4 inch diameter that is not restricted to the outside. The issue with the automatic cycle is that when the exhaust is restricted, it causes the heat, lint, and moisture to blow past the drum seals right back into the cabinet where it is passed through the basket again. The moisture keeps sensing the same moisture over and over. To prove the appliance has no issue, disconnect the duct and run it on an automatic cycle for about 10 minutes. You will see the timer advance. If flexible ducting is used there cannot be an excess wadded up behind the unit and the total length of the recommended solid ducting is the equivalent to 25 feet, (this is in consideration of each 90° turn being equivalent to 6 feet of straight ducting.

Read More...

1 Answer

Hello Sarge,
The case you are describing sounds like a ducting issue. You see, if the moisture cannot escape through the exhaust, it will be blown back into the cabinet past the drum seal. This will cause the unit to continue sensing the same moisture over and over. To prove if this is the case, remove the duct from the rear of the unit and run it on any automatic cycle for about 10 minutes. The timer will advance if this is the issue.

Read More...

1 Answer

Hello Chuck,
The length and configuration of the home ducting is the variance in the dry time. The shorter and straighter the duct, the faster the dryer can get rid of the moisture and the sooner the load will be complete.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google