Ray August 01, 2014 for Model Number Maytag A9800 Regarding a question previously asked to replace the part , my part broke off and the connecting wires are dangling loose. Does or matter where the ground is connected to the new part?
1 Answer Hello Ray. There si only 2 wires on the sensor bar. They can go to either spade. It is a closed circuit. Read More...
Lee C April 27, 2013 for Model Number mde9806ayw how to check a automatic dryer sensor for maytag dryer part # 304997 how to check with montor
1 Answer Lee, To test the dryness sensor bar with a meter, set the meter to the lowest resistance scale(RX1) and set one meter probe on one metal bar and one on the other metal bar, you should read an "open" circuit. Place a wet article or a metal object 9 a quarter works good) across the metal bars and the circuit should change to a "closed" circuit. You didn't mention an issue, cleaning the bar with rubbing alcohol, usually solves any sensor bar issues. Read More...
Don November 11, 2012 for Model Number LDG9824AAE Can you please give me detailed instructions on how to install the part? I also need to know what wires connect to the part.
1 Answer Hello Don, Unplug the unit from the power supply. Remove the two screws and raise the assembly up to access the wires. Now remove one wire and attach it to the new part. Disconnect the other wire and attach it to the new part. Re-install the two screws and re-connect the unit to the power supply. Read More...
J.H. February 23, 2012 for Model Number LDE8000ACW/A5122731 My dryer is not getting my clothes dry even though I can feel the heat in the clothes when I open the door. It doesn't make any difference where I set the timing control knob. Does this unit have a humidity control that controls the time of operation because the timer does not seem to make any difference in the drying?
2 Answers Hi J.H. If you notice moisture and lint collecting on the inside of the door panel, this means that you have a major vent clog issue. Look at the back of the unit before you pull it out. If you need to change from plastic to a flex-metal/rigid vent, it will increase the exhaust performance up to 30%. When it is clogged it backs up heat and holds moisture. The complaint will be that it takes too long to dry the clothes. Make sure the outside vent hood/cap is opening and closing properly also 4-5x /yr. Use a thermometer and check at the back of the cabinet vent for on temperatures of 125-130°. Off temperatures of 155-160°. This will tell you if the cycling thermostat part # WPY304475 and the heater part # WP307178 is working ok. Thank You. Read More...
J.H. February 23, 2012 for Model Number LDE8000ACW/A5122731 My dryer is not getting my clothes dry even though I can feel the heat in the clothes when I open the door. It doesn't make any difference where I set the timing control knob. Does this unit have a humidity control that controls the time of operation because the timer does not seem to make any difference in the drying?
2 Answers Hello J.W. Contrary to popular belief, the heat in the dryer does not dry the clothes. The air flow does. The heat is an assistance to the air flow. The heat evaporates the moisture but the air flow carries the moisture away from the clothes. In light of this information, I would recommend that you check your exhaust duct to ensure that it's not crimped or too long and complicated. The shorter and straighter the exhaust is, the faster the clothes will dry, the lower the electric bill will be, and the longer the dryer will last. Sure hope this helps you! Read More...
Les T. January 27, 2012 for Model Number Maytag LDG7600AAW My gas dryer will not automatically shut off except by using the timer. It is supposed to shut off automatically using a auto-dry setting on the control panel.
1 Answer Hello Les. You will need to test and see if there is power coming to the timer motor wires WPY308218. If so, you will need to replace the timer. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. Hope this helps. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Tim July 22, 2011 for Model Number Maytag DE 412 Recently I replaced the heating element assembly & high limit thermostat on this dryer. It is working again. However, I was shocked to find that if you stop the dryer to remove the contents before it reaches the end of the cycle (when the buzzer sounds)the heating element is staying on. Is there another sensor that may not be functioning? Also, the contents are still hot when the dryer stops, so I don't think it is going through the cool down cycle. Thanks very much for your help.
1 Answer Tim, did you replace the heater assembly (complete) WPY303404 or the heater element WPY313538? Sounds like you've got a shorted element or broken element insulator WPY303881. Or a shorted wire to the element, causing the element to have continuous heat. And there is a slight possibility that the timer heat circuit contacts are not opening at the end of the cycle. But it's most likely a shorted wire or element. Good Luck. Read More...